Installing Damper and Chimney System
20.
All chimney systems must be installed with an integrated
Damper System / Anchor Plate installed on top of the
fireplace. Installers are cautioned to put the chimney
system together exactly as instructed and shown in
chimney manufacturer’s guide. Any variations may have
serious consequences resulting in an accident or
malfunction. If instructions are not followed, the warranty
on the product will become null and void.
21. Apply a 1/4” bead of gasket cement around the base of
the Anchor Plate as shown below. Apply a 1” thick ceramic
fiber blanket to the gasket cement.
22. Apply balance of gasket cement in a 1/4” bead on top of
smoke dome approx. 1-1/2” around periphery of chimney
hole. Install damper assembly on top of unit pressing
damper and insulation blanket into cement. Secure with
four 1/4” X 1-14” masonry fastener.
23.Place chimney adapter onto top of damper plate and
center in opening using gasket supplied with adapter.
24. Attach adapter with screws supplied by carefully drilling
holes into damper plate.
25. Attach damper chain stop on center rear of lintel 3” (three
inch) vertical from opening using (3) #8 cement fasteners.
Attention
:
Clearance to combustible construction cannot
be reduced during course of construction. For the safe
operation of the finished fireplace, these clearances must
be followed when building the framework for the chimney
system.
Note that the most important aspect of the installation is
maintaining the minimum required clearances to combustible
materials according to the chimney pipe manufacturer’s
recommendations, otherwise a potential fire hazard may
occur.
Warning
:
do not interchange chimney manufacturer’s parts with an
other parts except those specifically required by the chimney
manufacturer’s recommendations otherwise a potential hazardous
condition may be created.
Attention
:
When choosing a Chimney System it must meet the foll
requirements:
Designed for installation in accordance with the National Fire Prote
Standard and UL 103.
Meets the requirements of NFPA 211.
Designed in accordance with ICC Codes.
Assuming you have sections of vertical pipe that are more
than 10’ (ten feet) measuring between elbows, you must
insert – at midpoint – a chimney stabilizer. When installing the
stabilizer, pull out the support straps with a good amount of
tension and hammer to the frame.
Firestop Radiation Shield
A Firestop Radiation Shield is required in multi-story
installations at each floor penetration above that where the
Support Box is located.
Firestop Radiation Shields also provide complete separation
from one floor space to another or attic space as required by
most codes. When the double wall pipe passes through a
framed opening into an attic space, the Firestop must be
placed into an attic floor as shown.