![mFi MASON-LITE MFP- 75 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/mfi/mason-lite-mfp-75/mason-lite-mfp-75_instructions-manual_1782261015.webp)
14
9. Rear walls are staggered on every row as shown.
10.After the third row of firebox is complete, install Downdraft
Diverter sections (MFP75-4A & B) as shown.
11.After the last side walls are installed, place #3 rebar (4
each, 36 inch long) vertically through the cells, into the
holes in the hearth, adjacent to the rebar and/or all-thread
sticking up from the hearth and fill all cells with Ready -
Mix concrete mix.
12.Set the Lintel and Lower Rear Dome in place as shown.
Each will be in two halves. There will be a 90 degree angle
iron, placed behind the lintel for support.
(Angle iron is not
included)
. Check that all is level. If you need to make
adjustments, use shims between the lowest wall
component and the top surface of the base plate. Once
leveled, fill any resulting gaps with mortar.
Important:
Adjustments can only be made while the mortar
is still wet when correcting for squareness and leveling.
13. Assemble Dome Sides (MFP75-7) as shown. The beveled
face lines up with the inward angles
of the lintel sides. Top
surfaces should be level.