Required Gas Pressure
The minimum inlet gas supply pressure for the purpose of input
adjustment is 7” of water column (w.c.) for natural gas.
The maximum inlet gas supply pressure is 10.5” w.c. for natural
gas.
A 1/8” NPT plugged tapping, accessible for test pressure
connection, must be provided immediately upstream of the gas
supply connection to the appliance.
Testing the Gas Supply System
The gas appliance and its required individual shut-off valve
must be disconnected from the gas supply piping system while
performing any tests of the piping system at pressures in excess
of 1/2 psig.
The gas appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
This is accomplished by closing the gas supply line valve
required by NFPA 54.
Important
To comply with building code acceptances, and for safe
operation and proper performance of this appliance, use ONLY
Mason-Lite parts and accessories.
Use of other controls, parts, and accessories which are not
designed for use with Mason-Lite gas appliances is prohibited
and will void all warranties, certifications, listings, and building
code approvals, and may cause property damage, personal
injury, or loss of life.
The burner specified for use with this gas appliance is non-
convertible and only meant to be used with the gas listed on the
rating plate.
GUIDELINES FOR USE:
All current and future users of Mason-Lite Appliances
are charged with the responsibility for full knowledge of the
information contained within this manual which includes:
•
Strict requirements for assembly.
• Detailed instructions for installation.
• Cautionary guidelines for use.
• On-going maintenance instructions.
It is the responsibility of the distributor, subcontractor and/
or the general contractor – whoever shoulders the liability
for installation of this product – to see to it that the work is in
complete compliance with the guidelines and instructions in this
manual.
Note that the general contractor is the party accountable for
seeing that adequate clearances are provided from all firebox
surfaces per specifications in this manual.
DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS
NOT SPECIFIED FOR USE WITH THIS APPLIANCE.
The Mason-Lite B-vented Gas Appliance is Designed for
Use Only with:
- The specified burner and gas log system
- Plumbed Natural Gas.
DO NOT USE OR STORE GASOLINE OR OTHER FLAMMABLE
LIQUIDS OR GASES IN OR NEAR THIS APPLIANCE!
ATTENTION
: A fire or an explosion could occur causing property
damage, injury or loss of life if you do not follow the information
in this manual!
This appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70.