Operating Instructions
Stapling Plier pneumatic
130/1916 P/PU/PUX | 130/2516 P/PU/PUX
Page:
7
Mod.:
02/2019
ET
543
Seite 7 von 8 14.02.19 P:\Technik\ZANGEN\Zange 130\Bedienungsanleitung\englisch\Manual 130-1916 P Pneum engl 02_2019.docx
14
Maintenance and care
ATTENTION!
Before every maintenance, the compressed air supply must be removed.
Only original spare parts from the manufacturer are to be used
(see appendix "Spare parts list").
In order to maintain the operational readiness and function of the stapler, it must be regularly checked
and cleaned by the operator or by qualified personnel.
All friction points/movable parts should be lightly oiled from time to time.
Proper care helps to keep the stapler / stapler in good working order over time. The stapler / stapler
should be thoroughly cleaned at least once a week.
• Do not use aggressive cleaning agents or solvents (damage seals),or even emery paper used for
cleaning.
• Cleaning with compressed air is also to be avoided as there are dirt particles
get into the sealing areas and damage them.
• Do not use footwash for cleaning.
Soiling must be removed directly from the operator after machining operations.
Dirt on the workpieces can be blown off.
Any kind of alteration to the device (e.g. drilling of holes) is only permitted with
prior consent and written permission of the manufacturer.
Only ORIGINAL spare parts
may be used. (see “spare parts list”)
In case no ORIGINAL spare parts are used each warranty claim, or any liability is excluded!
15
Malfunction detection
During any kind of defect, the machine is to be shut down and separated from the
pressurized air supply until the flawless operation is ensured again.
Please do not
try to dismantle or repair the machine.
No stapling occurred or the staple wasn't fully bent, or it remains in the stapler:
No.
Cause:
Troubleshooting:
1. Air pressure too low.
During the stapling 4 - 6 bar overpressure, Check hoses
and valves and ensure that the tool has a sufficient air
supply.
2. Air cleanliness inadequate
Connect a maintenance unit upstream consisting of a
pressure regulator and water separator.
3. Staple is jammed in the tool and is not
preformed.
Air pressure too low (see item 5).
Stapling head too quick.
Remove
all
the staples from the stapling head and clean the device from deposits in soiling.
Reconnect the air supply.
Now you can use the stapling device to the full extent again.
In the event of a malfunction, which is more extensive than just some jammed
staples, please contact us.
The tool will be examined by our specialists and the
malfunction will be remedied.