36
37
24
7, 12, 13, 15, 16, 17, 19, 20, 21
SAFETY PRECAUTIONS -
See pages 2-3 for definitions
TROUBLESHOOTING GUIDE
Troubleshooting Guide for The Path Pro
2
Electric Lift
(Linear Actuator)
CONDITION
POSSIBLE CAUSE
CORRECTION
Plow operates
1. Bad wire connections.
1. Clean/Tighten wire connections.
slowly
2. Discharged battery.
2. Recharge battery.
3. Bad Linear Actuator.
3. Replace Linear Actuator.
4. Bad Remote Control Receiver. 4. Replace Receiver
.
Plow doesn’t
1. Bad wire connections.
1. Clean/Tighten wire connections.
operate
2. Discharged battery.
2. Recharge battery.
3. Bad Linear Actuator.
3. Replace Linear Actuator.
4. Bad Remote Control Receiver. 4. Replace Receiver.
5 Remote not communicating
5. Re-sync to receiver .
with receiver.
6. Battery dead on Remote Control. 6. Replace Battery and re-sync to receiver.
7. Bad Remote Control.
7. Replace remote and re-sync to receiver.
Re-sync instructions:
1. Make sure receiver is plugged in and has 12 volts.
4. Press the up and down button on remote simultaneously.
The receiver is now communicating with the remote.
36
Содержание Path Pro2
Страница 9: ...9 A B C D E H I J J K L M N O P Q R S T F G Manual Lift Plow Models 23120 23115 23110 23175...
Страница 11: ...11 A B C D E F G H I J J L M N T R S U Electric Lift Plow Models 23220 23215 23210 23275 Q...
Страница 33: ...33 PARTS LIST PATH PRO2 Manual Lift 33...
Страница 35: ...35 PARTS LIST PATH PRO2 Electric Lift 35...
Страница 41: ...41 41...
Страница 42: ...42 Notes 42...
Страница 43: ...43 Notes 43...