environment, since they have no cadmium.
• 4 alkaline-manganese dry cell batteries 1.5V, type IEC LR6 (size AA).
Maintenance-free power source for moderate power requirements.
• 4 lithium batteries 1.5V, type IEC FR6 (size AA). Maintenance-free high-capa-
city power source with a low self-discharge rate.
• Power Pack P76 with connecting cable V58-50 (optional accessory)
If your flash unit is not going to be used for an extended period of time,
remove the batteries.
Replacing batteries
The batteries are flat or dead if the recycling time (elapsing from the triggering
of a full-power flash, e.g. in the M mode, to the moment the flash ready indica-
tor
lights up again) exceeds 60 seconds.
• Turn off the flash unit at the main switch
.
• Slide the battery compartment cover
downwards and fold open.
• Insert the batteries lengthwise as indicated by the battery symbols on the flash
unit, and close the battery compartment cover
.
When inserting batteries, ensure that the polarity is correct and matches
the symbols in the battery compartment. Inserting the batteries in the
wrong direction can destroy the flash unit!
Always replace all batteries simultaneously, and make sure that batteries
are the same brand and have the same capacity.
Flat or dead batteries should not be disposed of with ordinary household
waste. Help protect the environment, and dispose of flat/dead batteries
at the appropriate collection points.
☞
☞
3.3 Switching the flash unit on and off
The flash unit can be turned on by flipping the main
switch
to the „ON“ position.
To turn off the flash unit, flip the main switch
to the
left position.
If your flash unit is not going to be used for an extended period of time,
we recommend turning it off with the main switch and removing the
power source (i.e., batteries).
3.4 Power Pack P76 (optional accessory)
If a battery-operated flash does not meet your needs in terms of number of flas-
hes and recycling times, a Power Pack P76 (optional) can be connected to the
flash unit to provide extra power. A V58-50 connecting cable (optional) is
necessary for connecting the Power Pack P76 to the flash unit.
In this case, no batteries have to be inserted into the flash unit.
When attaching the Power Pack P76 or the V58-50 connecting cable (accesso-
ry) to the flash unit, the main switch of the flash must be in the left „OFF“ posi-
tion.
The flash unit is then turned on or off using the switch on the Power Pack P76
(see Operating Instructions for the Power Pack).
To protect the flash unit from thermal overload when connected to the
Power Pack, a monitoring control increases the recycling times during
heavy usage. Both flash unit and Power Pack should be switched off
before the connecting cable is attached or removed from either unit.
☞
☞
☞
✴
709 47 0237.A1 58AF-2 Pen/Sam 27.07.2010 15:17 Uhr Seite 113
Содержание MECABLITZ 58 AF-2 digital
Страница 73: ...73 ĸ 2 Pen Sam 27 07 2010 15 17 Uhr Seite 73 ...
Страница 109: ...109 ń 2 Pen Sam 27 07 2010 15 17 Uhr Seite 109 ...
Страница 145: ...145 ķ 2 Pen Sam 27 07 2010 15 17 Uhr Seite 145 ...
Страница 181: ...181 ƴ 2 Pen Sam 27 07 2010 15 17 Uhr Seite 181 ...
Страница 217: ...217 į 2 Pen Sam 27 07 2010 15 18 Uhr Seite 217 ...
Страница 218: ... 2 Pen Sam 27 07 2010 15 18 Uhr Seite 218 ...
Страница 219: ...219 2 Pen Sam 27 07 2010 15 18 Uhr Seite 219 ...
Страница 220: ... 2 Pen Sam 27 07 2010 15 18 Uhr Seite 220 ...
Страница 221: ...221 2 Pen Sam 27 07 2010 15 18 Uhr Seite 221 ...
Страница 229: ......