METSYS ML2/3 LINE LASER OPERATTING MANUAL 

 

Pulse Mode 

•  Under  pulse  mode,  Laser  tool  can  work  with  a  laser  detector  for  working  in  a  brighter 
environment or a larger working distance. 

 

Under Pulse model, the laser beam will enter into power-saving condition, which leads to 
longer  battery  life.  Users  are  recommended  to  use  this  model  for  green  beam  in  indoor 
uses.   

 
• Turn on the laser tool, short press of the Pulse button will turn the Pulse Mode on and the LED 
Indicator will light up. The laser beam is dimmer in pulse mode. 
•  Press  and  hold  the  Operation  Button  again  for  3  seconds  to  back  Normal  Mode,  and  the 
brightness of the laser line will return to normal. 
• Please turn on the pulse mode when using the laser detector. 
 
 
 

Specifications 

Model 

ML-2Red Beam 

ML2P Red Beam 

ML2PG Green Beam

 

Laser Wavelength 

635-660nm 

510-520nm ( Dot:

 

635-650nm)

 

Laser Class 

Class 2 (IEC/EN60825-1/2014), ≤1mW

 

Leveling Accuracy

 

±3mm/10m

 

±3mm/10m

 

Horizontal/Vertical Accuracy 

Plumb Dot Accuracy 

±3mm/10m

 

Fan angle   

H: 360 

° / V: 140°

 

Leveling/Compensation 
Range 

±3.5°

 

Operation 

Temperature 

Range 

0

~

45

 

Storage Temperature Range 

-20

~

60

 

Operating  Time  (all  laser 
beams on) 

Approx 10 Hours 

Approx 7 Hours 

Approx 4hrs ( 4AA) / 

10hrs ( Rechargeable) 

Working Distance (Line) 

30m 

30m 

30m 

Working Distance (Dot)

 

N/A 

50m 

50m 

IP Rating 

IP54

 

Mount Size 

1/4”-20&5/8”-11

 

Power Source 

4×˝AA˝ (LR6) / Rechargeable Battery (LR6)

 

Note: 

Appearance and specifications may differ due to product improvement. 
Working distance varies depending on the operating environment. 
Battery life depends on battery capacity and quality, it is recommended to use a large capacity 
battery. 

Содержание ML2

Страница 1: ...or Window Leveling Height Transfer Point Transfer Square Layout Pulse Power saving Model Slope Application ML2 2P 2PG Product Overview 1 Laser Switch button 2 Pulse button 3 LED indicator 4 Laser Horizontal port 5 Laser Vertical port 6 Plumbing Dots port 7 Pendulum Transit Lock 8 1 4 5 8 threaded mount 9 Battery cover 10 Main switch Button ...

Страница 2: ...tive surface as the laser beam could be projected into your eyes or into the eyes of others While the product is in operation be careful not to expose your eyes to the emitting laser beam Green Red light source Exposure to a laser beam for an extended time may be hazardous to your eyes Do not attempt to view the laser beam through optical tools such as telescopes as serious eye injury may result D...

Страница 3: ...e of plastics and may become deformed at high temperatures Exterior plastic parts may be cleaned with a damp cloth Although these parts are solvent resistant NEVER use solvents Use a soft dry cloth to remove moisture from the tool before storage Store the tool in its case when not in use If storing for extended time remove batteries before storage to prevent possible damage Do not dispose of this ...

Страница 4: ...If the laser tool is in self leveling mode Slide the side switch to the Locked Position to turn laser tool OFF If the laser tool is in manual mode Method 1 Slide the side switch to the Unlocked Position and then slide the pendulum again to the Locked Position to turn laser tool OFF Method 2 Short press of the operation button to switch the laser line in order After Down Dot Up Dot short press of t...

Страница 5: ...using the laser detector Specifications Model ML 2Red Beam ML2P Red Beam ML2PG Green Beam Laser Wavelength 635 660nm 510 520nm Dot 635 650nm Laser Class Class 2 IEC EN60825 1 2014 1mW Leveling Accuracy 3mm 10m 3mm 10m Horizontal Vertical Accuracy Plumb Dot Accuracy 3mm 10m Fan angle H 360 V 140 Leveling Compensation Range 3 5 Operation Temperature Range 0 45 Storage Temperature Range 20 60 Operati...

Страница 6: ... leveling mode in default Method 2 When the side switch is in the Locked Position press button and hold for 2 seconds to turn on the laser tool Turn on horizontal line and manual mode in default Lines switching Turn on the laser tool short press of the button repeatedly to switch the composition of different laser lines Laser line will switches in the following order One Horizontal Line default On...

Страница 7: ...p short press of the button again to turn laser tool OFF Note The laser level can only be turned off when the side switch is in the Locked Position Self leveling Mode is enabled when the laser tool is switched to the unlocked position has laser plumb blink fast when tool is out of self leveling range 3 5 Note When using Self leveling mode please place this laser tool on a level surface Manual Mode...

Страница 8: ...RATTING MANUAL Operating Time all laser beams on Approx 8 hrs Approx 3 hrs 7hrs Rechargeable Mount Size 1 4 20 Power Source 4 AA LR6 Rechargeable LR6 IP Rating IP54 Operation Temperature Range 0 45 Storage Temperature Range 20 60 ...

Отзывы: