metrofires Classic Rad Скачать руководство пользователя страница 7

7

Minimum clearances

All Metro wood fires comply with AS/NZS2918:2001. Minimum clearances 
shown below are detailed in millimetres, with a Pioneer double flue 
shield fitted to the appliance. Measurements are taken from the following 
reference points as illustrated:

-     From the nearest combustible wall or surface (A, B, D, E, G, H)
-     From the Metro’s flue centre (A, B, C, D)
-     From the Metro’s cabinet/heatshield outermost point (E, F, G, H)
-     To the edge of the ash floor protectors non-combustible surface 

(C, F, I, J, K, L, M)

AS/NZS2918:2001 allows for a reduction in minimum clearances as 
detailed in Section 3, tables 3.1 and 3.2 of the standard.

Some Metro models have undergone additional testing which allows for 
reduced clearances. Please see the footnotes below the clearance table for 
the applicable models.

Wetback connections (taken facing the Metro/wall)

•   ECO Tiny Ped and ECO Tiny Rad models are 92mm left of the flue centre
•  The Tiny Rad Woody model is 184mm left of the flue centre
•   Wee Series models are 226mm left of the flue centre
•   The Classic Rad model is 184mm left of the flue centre
•   All other models are 140mm left of the flue centre

Specifications were correct at the time of printing, but may alter and those 
detailed within should be used only as a guide. If in doubt, please consult 
your Metro retailer or metrofires.co.nz.

Minimum installation clearances with a Pioneer double flueshield fitted (mm)

Wetback

Dimensions

Clean air models

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

Width Depth Height

ECO Tiny Ped

210

430

580

290

25

230

185

60

790

650

990

875

250

280

470

490

500

665

ECO Tiny Rad

225

552

580

420

150

230

300

75

805

650

1165

925

250

280

470

505

500

665

Tiny Rad Woody

251

568

580

382

110

230

310

100

831

650

1120

880

250

365

555

515

498

758

R1

243

774

586

554

280

244

530

100

829

825

1370 1118

425

N/A

N/A

488

485

668

R2

246

858

626

582

275

235

570

100

872

905

1449 1203

505

N/A

N/A

575

537

690

Wee Rad 

1

 

251

568

580

455

150

230

260

100

831

825

1224 1015

425

295

485

615

501

688

Wee Rad Base

271

678

580

489

180

230

370

120

851

825

1270 1049

425

295

485

615

501

691

Wee Rad Woody

271

708

580

509

200

230

400

120

851

825

1285 1069

425

365

555

615

501

758

Wee Ped 

2

263

651

580

490

170

230

350

110

843

825

1274 1050

425

295

485

602

503

665

Classic Rad 

3

257

695

780

500

220

229

430

100

1037

728

1487 1168

328

393

583

530

707

680

Xtreme Ped

251

624

630

441

110

227

280

100

881

907

1254 1065

507

312

502

688

554

721

Xtreme Rad

251

650

630

458

100

227

280

100

881

907

1277 1077

507

312

502

740

554

743

Xtreme Rad Base

251

650

630

458

100

227

280

100

881

907

1277 1077

507

312

502

740

554

743

Xtreme Rad Woody

251

680

630

478

120

227

310

100

881

907

1292 1097

507

382

572

740

554

813

Mega Rad

285

720

728

497

100

224

300

130

1013 1006 1431 1227

606

300

490

840

659

744

LTD rural models

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

Width Depth Height

LTD Wee Rad 

251

548

580

425

120

230

240

100

831

825

1180

985

425

295

485

615

501

688

LTD Wee Rad Base

251

658

580

489

180

230

350

100

831

825

1270 1049

425

300

490

615

501

691

LTD Wee Rad Woody

271

708

580

509

200

230

400

120

851

825

1285 1069

425

360

550

615

501

758

LTD Xtreme Rad

251

650

630

458

100

227

280

100

881

907

1277 1081

507

350

540

740

554

743

LTD Xtreme Rad Base

251

650

630

458

100

227

280

100

881

907

1277 1081

507

350

540

740

554

743

LTD Xtreme Rad Woody

251

680

630

478

120

227

310

100

881

907

1292 1097

507

420

610

740

554

813

LTD Mega Rad

285

720

728

497

100

224

300

130

1013 1006 1431 1227

606

300

490

840

659

744

The Wee Rad installed with a Pioneer double flue shield with the Wee Rad corner wing shields fitted allows for reduced clearances as follows:

1

  Wee Rad corner clearance (E) can be reduced to 120mm. This in turn also reduces clearances (D) to 425mm, (K) to 1180mm and (L) to 985mm. When fitting the corner wing 

shields, the Wee Rad itself must be installed to a corner clearance (E) of 120mm. The corner wing shields are then fitted which gives a wall to shield corner clearance of 100mm.

The following models installed with a Pioneer double flue shield with the side extensions fitted allows for reduced clearances as follows:

2

  Wee Ped corner clearance (E) can be reduced to 115mm. This in turn also reduces clearances (D) to 436mm, (K) to 1197mm and (L) to 996mm. 

3

  Classic Rad corner clearance (E) can be reduced to 180mm. This in turn also reduces clearances (D) to 460mm, (K) to 1430mm and (L) to 1127mm.

Metro clearances and specifications 

(Minimum clearances shown are in mm, with a Pioneer double flue shield fitted)

Содержание Classic Rad

Страница 1: ...fire in your home 9 Optional wetbacks 9 Getting to know your Metro fire 10 Operating your Metro fire 10 Cleaning and maintenance 11 Troubleshooting 12 Metro Fires warranty 13 Replacement parts 14 15 H...

Страница 2: ...ocated this manual familiarise yourself with the illustrations on pages 2 3 and proceed as follows Metro radiant fires These Metro s are supplied virtually fully assembled Packed inside the firebox yo...

Страница 3: ...ning with one hand holding the flue spigot with the other slowly lift the front of the wood fire all the way back and rest the wood fire on its rear heat shield on the floor Remove the packaging palle...

Страница 4: ...f the installation is within New Zealand seismic restraint is required Using masonry anchors if the floor protector is on a concrete floor or coach bolts if a wooden floor secure through the holes pro...

Страница 5: ...the flue pipe must also be sealed into the Metro fires flue outlet This is critical for optimum operation All Metro fires have been tested with a Pioneer double flue shield For the Metro fire to be i...

Страница 6: ...oints 4 A further three bolt heads will also be visible on the inside rear wall of the firebox these are threaded into the 6mm thick firebox Remove all three 5 Using the tube of sealant supplied with...

Страница 7: ...365 555 615 501 758 Wee Ped 2 263 651 580 490 170 230 350 110 843 825 1274 1050 425 295 485 602 503 665 Classic Rad 3 257 695 780 500 220 229 430 100 1037 728 1487 1168 328 393 583 530 707 680 Xtreme...

Страница 8: ...missing bricks baffle plate promet extension white board on the baffle plate It is critical that the fire not be operated with cracked or broken door glass Please note the above 3 points require regul...

Страница 9: ...our Metro alternative wetbacks will void the Metro s emission approvals and may seriously affect the performance of the appliance and void its warranty Other considerations are Distance from your Metr...

Страница 10: ...ter content and ensure surface area combustion Do not turn the air control down lower than you need to if you want the Metro to burn overnight endeavour to obtain an 8 hour burn time not 12 hours It w...

Страница 11: ...build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar empty the excess ash...

Страница 12: ...ntal and can be caused by many variables and it is purely trial and error to ascertain the cause Air turbulence and or negative air pressure influences around the flue termination can be caused by too...

Страница 13: ...be reduced If your Metro wood fire has been neglected by not being regularly maintained and serviced warranty may be declined It is critical the fire not be operated with over worn faulty or missing...

Страница 14: ...t required Type of steel baffle s required Wetback options ECO Tiny Ped ECO Tiny Rad Tiny Promet 500 1550 Tiny Baffle 500 2050 2kW Wetback 450 0050 Tiny Rad Woody Tiny Woody Promet Set 500 2004 Tiny W...

Страница 15: ...d Woody Xtreme Ped Xtreme R2 Promet Set 500 2010 Xtreme R2 Front Baffle 500 2510 Xtreme R2 Rear Baffle 500 2515 3kW Wetback 450 0100 Mega Rad Mega Rad Promet Set 500 2020 Mega Rad Front Baffle 500 253...

Страница 16: ...l models which is generally required when applying for a building consent See your Metro retailer to obtain a copy or visit www metrofires co nz metrofires co nz Visit the Metro website metrofires co...

Отзывы: