7
Minimum clearances
All Metro wood fires comply with AS/NZS2918:2001. Minimum clearances
shown below are detailed in millimetres, with a Pioneer double flue
shield fitted to the appliance. Measurements are taken from the following
reference points as illustrated:
- From the nearest combustible wall or surface (A, B, D, E, G, H)
- From the Metro’s flue centre (A, B, C, D)
- From the Metro’s cabinet/heatshield outermost point (E, F, G, H)
- To the edge of the ash floor protectors non-combustible surface
(C, F, I, J, K, L, M)
AS/NZS2918:2001 allows for a reduction in minimum clearances as
detailed in Section 3, tables 3.1 and 3.2 of the standard.
Some Metro models have undergone additional testing which allows for
reduced clearances. Please see the footnotes below the clearance table for
the applicable models.
Wetback connections (taken facing the Metro/wall)
• ECO Tiny Ped and ECO Tiny Rad models are 92mm left of the flue centre
• The Tiny Rad Woody model is 184mm left of the flue centre
• Wee Series models are 226mm left of the flue centre
• The Classic Rad model is 184mm left of the flue centre
• All other models are 140mm left of the flue centre
Specifications were correct at the time of printing, but may alter and those
detailed within should be used only as a guide. If in doubt, please consult
your Metro retailer or metrofires.co.nz.
Minimum installation clearances with a Pioneer double flueshield fitted (mm)
Wetback
Dimensions
Clean air models
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Width Depth Height
ECO Tiny Ped
210
430
580
290
25
230
185
60
790
650
990
875
250
280
470
490
500
665
ECO Tiny Rad
225
552
580
420
150
230
300
75
805
650
1165
925
250
280
470
505
500
665
Tiny Rad Woody
251
568
580
382
110
230
310
100
831
650
1120
880
250
365
555
515
498
758
R1
243
774
586
554
280
244
530
100
829
825
1370 1118
425
N/A
N/A
488
485
668
R2
246
858
626
582
275
235
570
100
872
905
1449 1203
505
N/A
N/A
575
537
690
Wee Rad
1
251
568
580
455
150
230
260
100
831
825
1224 1015
425
295
485
615
501
688
Wee Rad Base
271
678
580
489
180
230
370
120
851
825
1270 1049
425
295
485
615
501
691
Wee Rad Woody
271
708
580
509
200
230
400
120
851
825
1285 1069
425
365
555
615
501
758
Wee Ped
2
263
651
580
490
170
230
350
110
843
825
1274 1050
425
295
485
602
503
665
Classic Rad
3
257
695
780
500
220
229
430
100
1037
728
1487 1168
328
393
583
530
707
680
Xtreme Ped
251
624
630
441
110
227
280
100
881
907
1254 1065
507
312
502
688
554
721
Xtreme Rad
251
650
630
458
100
227
280
100
881
907
1277 1077
507
312
502
740
554
743
Xtreme Rad Base
251
650
630
458
100
227
280
100
881
907
1277 1077
507
312
502
740
554
743
Xtreme Rad Woody
251
680
630
478
120
227
310
100
881
907
1292 1097
507
382
572
740
554
813
Mega Rad
285
720
728
497
100
224
300
130
1013 1006 1431 1227
606
300
490
840
659
744
LTD rural models
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Width Depth Height
LTD Wee Rad
251
548
580
425
120
230
240
100
831
825
1180
985
425
295
485
615
501
688
LTD Wee Rad Base
251
658
580
489
180
230
350
100
831
825
1270 1049
425
300
490
615
501
691
LTD Wee Rad Woody
271
708
580
509
200
230
400
120
851
825
1285 1069
425
360
550
615
501
758
LTD Xtreme Rad
251
650
630
458
100
227
280
100
881
907
1277 1081
507
350
540
740
554
743
LTD Xtreme Rad Base
251
650
630
458
100
227
280
100
881
907
1277 1081
507
350
540
740
554
743
LTD Xtreme Rad Woody
251
680
630
478
120
227
310
100
881
907
1292 1097
507
420
610
740
554
813
LTD Mega Rad
285
720
728
497
100
224
300
130
1013 1006 1431 1227
606
300
490
840
659
744
The Wee Rad installed with a Pioneer double flue shield with the Wee Rad corner wing shields fitted allows for reduced clearances as follows:
1
Wee Rad corner clearance (E) can be reduced to 120mm. This in turn also reduces clearances (D) to 425mm, (K) to 1180mm and (L) to 985mm. When fitting the corner wing
shields, the Wee Rad itself must be installed to a corner clearance (E) of 120mm. The corner wing shields are then fitted which gives a wall to shield corner clearance of 100mm.
The following models installed with a Pioneer double flue shield with the side extensions fitted allows for reduced clearances as follows:
2
Wee Ped corner clearance (E) can be reduced to 115mm. This in turn also reduces clearances (D) to 436mm, (K) to 1197mm and (L) to 996mm.
3
Classic Rad corner clearance (E) can be reduced to 180mm. This in turn also reduces clearances (D) to 460mm, (K) to 1430mm and (L) to 1127mm.
Metro clearances and specifications
(Minimum clearances shown are in mm, with a Pioneer double flue shield fitted)