6. Installation
6.1. General
The appliance is designed to function in locations with temperatures of 10°C to 35°C.
The appliance must not be installed close to appliances that generate heat, e.g. ranges.
6.2. Storage
The appliance should be stored in a dry place, at a temperature over +1°C. If the appliance has been
exposed to a temperatures below 0°C, it must be drained (allowed to melt). After melting, before taking
the appliance into use, make sure that there is no damage to or leakage in piping.
Electronic faucet: It is essential to take care that water in the faucet and solenoid valve does not freeze.
6.3. Unpacking the appliance
The appliance should be transported to the installation site in its transport package. Do not remove pack-
ing until just before installation to prevent dust in the installation place from damaging the appliance. The
appliance should be stored and transported in an upright position.
6.4. Installation
The appliance should be placed in a well ventilated room. Avoid placing the appliance in direct sunlight.
The appliance must be installed in a vertical position with an accuracy of ±3°. Greater skewness may
cause malfunctions.
When installing D-I models care must be taken that the machinery is not positioned directly on the fl oor,
but an air gap of at least 10 cm is left between the machinery and the fl oor. This is to make sure that
water, possibly dripping onto the fl oor, would not damage the electrical components of the machinery
and cause hazardous situations.
The compressor is equipped with damping of vibrations, but in some cases vibrations can transfer to
other structures. A rubber mat placed under the appliance can absorb vibrations and noise (needed in
special cases only).
The thermostat has been set at the factory for ordinary operating circumstances.
When installing refrigerated D-I models, special attention must be paid to condenser air circulation.
Make sure that the condenser air inlet is not blocked and that warm air can freely exit the compressor
compartment. The temperature of inlet air is of crucial importance to the cooling effect of the appliance.