METOS WATER DISPENSER

7. Troubleshooting

In case the appliance does not function as expected, review the following list of problems to fi nd out if 
the appliance can be put in order without a service call. In this way you can avoid unnecessary service 
calls and costs. In all enquiries, please contact the nearest Metos service. Most problems can be mana-
ged on the phone.

POBLEM

POSSIBLE CAUSE

ACTION

No water comes out of
the faucet

Water line obstructed (faucet is 
closed)

Open the faucet

Not enough water in the tank

Check and fi ll

Too little water coming

Filter  (option)  clogged  (water 
fl ow gradually decreases)

Replace the fi lter

Water fl ow adjusted to a too low 
fl ow rate

Adjust the fl ow rate correctly

Too much water coming

Water fl ow wrongly adjusted

Adjust the fl ow rate correctly.

Water is warm

Power cable is not properly plug-
ged in the socket

Put the cable properly in the 
socket

Defective fuse

Replace the fuse

Condenser covered by dust

Clean the condenser

Defective thermostat

Call the service

Defective compressor

Call the service

The cooler is installed in a too 
warm environmet or otherwice 
not suitable location

Call the service

The appliance does not contain parts that can be serviced by the user. Service must be carried out by an 
authorised service company.

STOP

Содержание PROFF D-I WD

Страница 1: ... N D I WD EN D I WD 2 D I WD E2 D I WD N2 D I WD EN2 4213317 4213319 4213321 4213323 4213325 4213327 4213329 4213331 4213341 4213342 4213343 4213344 4319228 4319230 4319232 4319234 4319408 4319410 4319412 4319414 4309870 4309872 4309874 4309876 4309878 4309880 4309882 4309884 4309886 4309888 4309890 4309892 4309894 4309896 4309898 4309899 ...

Страница 2: ... 5 5 Operating instructions 6 5 1 Operation 6 5 2 After operation 6 5 2 1 Cleaning the exterior surfaces 6 5 2 2 Cleaning the condenser to be performed by a service technician 6 5 2 3 Replacing the filter option to be performed by a service technician 6 6 Installation 7 6 1 General 7 6 2 Storage 7 6 3 Unpacking the appliance 7 6 4 Installation 7 6 4 1 Opening for the drip basin D I models 8 6 5 Ele...

Страница 3: ...s Not complying with the above may put the safety of the appliance in danger 2 1 Symbols used in the manual This symbol informs about a situation where a safety risk might be at hand Given instructions are man datory in order to prevent injury This symbol informs about the right way to perform in order to prevent bad results appliance damages or hazardous situations This symbol informs about recom...

Страница 4: ...dates the manufacturer s product liability Dangerous situations may arise if the given instructions are not followed The manufacture declines all responsibility for any operations carried out on the appliance without following the instructions in this manual 3 2 Disposal of the appliance The appliance contains parts and components the disposal of which requires special treatment Contact local auth...

Страница 5: ... I WD 2 D I WD E2 D I WD N2 D I WD EN2 are delivered without an outer casing and are designed for insertion into a line structure The top has a faucet and a basin with a drain for drip water 4 2 1 Electronic faucet models PWD 04A E PWD 04A EN D I WD E D I WD EN The faucet is turned on and off by means of a solenoid valve actuated by a photocell When a glass is held within the photoce ll s sensing ...

Страница 6: ...ecreases and the condensing temperature rises Finally condenser clogging can damage the compressor When cleaning the condenser with a brush be careful not to damage the condenser The condenser can also be cleaned using a vacuum cleaner 5 2 3 Replacing the filter option to be performed by a service technician If the appliance is supplied with an optional filter we recommend replacing it at the interv...

Страница 7: ...n The appliance should be placed in a well ventilated room Avoid placing the appliance in direct sunlight The appliance must be installed in a vertical position with an accuracy of 3 Greater skewness may cause malfunctions When installing D I models care must be taken that the machinery is not positioned directly on the floor but an air gap of at least 10 cm is left between the machinery and the flo...

Страница 8: ...e marked on the pictures with solid lines and the shape of the drip basin with broken lines Ensure sufficient air inlet air circulation for the condenser Condenser air circulation Do not mount the condenser on a closed plinth as this will prevent condenser air circulation Air venting takes place below the appliance and air intake at the front Do not block the condenser air inlets D I WD E2 D I WD E...

Страница 9: ...ater supply pressure is above 5 bar The connection of the appliance to the water supply must be carried out by qualified persons only NOTE Do not remove the spacer ring of the electronic faucet during installation 6 5 Electrical connections The appliance is designed to function in the electrical power network 1 N PE AC 230V 50Hz Connect the appliance to the power supply with an earthed socket 6 6 F...

Страница 10: ...vice technician or installer 6 9 Adjusting the water flow electronic faucet To be performed by an authorised service technician or installer Water filling rate can be adjusted with the help of a screw 1 located on top of the faucet by turning the screw with a screwdriver If after installation some air comes out of the faucet allow water to run until no air is coming and the water is clear ...

Страница 11: ...d fill Too little water coming Filter option clogged water flow gradually decreases Replace the filter Water flow adjusted to a too low flow rate Adjust the flow rate correctly Too much water coming Water flow wrongly adjusted Adjust the flow rate correctly Water is warm Power cable is not properly plug ged in the socket Put the cable properly in the socket Defective fuse Replace the fuse Condenser covere...

Страница 12: ...17 4 2014 Rev 3 3 METOS WATER DISPENSER 12 8 Technical specifications Refrigeration circuit diagram Connection diagram S00354 A3 Connection diagram S00196 A2 Dimensions machinery Installation drawing ...

Страница 13: ... 13 17 4 2014 Rev 3 3 METOS WATER DISPENSER Refrigeration circuit diagram Condenser Compressor Capillary tube Drier Heat exchanger ...

Страница 14: ...17 4 2014 Rev 3 3 METOS WATER DISPENSER 14 Connection diagram S00354 A3 Switch wit signal light Pump Compressor Condenser fan Thermostat ...

Страница 15: ...Connection diagram S00196 A2 ...

Страница 16: ...17 4 2014 Rev 3 3 METOS WATER DISPENSER 16 Dimensions machinery ...

Страница 17: ... 17 17 4 2014 Rev 3 3 METOS WATER DISPENSER Installation drawing Mechanical Neutral and cooling Electronic Neutral and cooling Rev 3 2 ...

Страница 18: ... N PE AC 230V 50Hz Power input Cooling and electronic 0 16 kW Extraction capacity Cooling 180 W 7 54 Exterior Cooling R134a Ulkovuoraus All Stainless steel Control unit Cooling Thermostat Capacity 40 litres hour Drain Floor drain Water connection Cold water max 5 bar Sensing range Electronic preset range 0 40 cm ...

Страница 19: ... 19 17 4 2014 Rev 3 3 METOS WATER DISPENSER ...

Страница 20: ......

Отзывы: