Model TWBS.EW.H 

Page 1 of 11 

 

 

 

 

 

 

1455 Kleppe Lane 

Sparks, NV 89431-6467 

(775) 359-4712 

Fax (775) 359-7424 

E-mail

[email protected]

 

 

website

www.hawsco.com

 

 

No. 0002080380 (12) 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 

 

 

 
 

 

IF YOU NEED ASSISTANCE FROM OUR TECHNICAL SERVICE DEPARTMENT,  MAKE 
SURE YOU CAN IDENTIFY THIS WATER HEATER BY HAVING THE  SERIAL NUMBER. 

 

Model No. TWBS.EW.H 

 

Serial  No.   

 

 

 
 

 

INSTALLER/ CONSUMER RESPONSIBILITIES 

 

PLEASE TAKE THE TIME TO READ NOT ONLY THIS MANUAL BUT ALSO 

THE  WARRANTY CARD ENCLOSED. WARRANTY OF THIS HEATER WILL DEPEND ON 

PROPER  INSTALLATION, OPERATION, AND REQUIRED MAINTENANCE. THE 

WARRANTY SHALL BE  VOID IF THE DESIGN OR STRUCTURE OF THE WATER 

HEATER HAS BEEN ALTERED IN  ANY WAY WHATSOEVER. THE MANUFACTURER OF 

THIS WATER HEATER WILL NOT BE  LIABLE FOR ANY DAMAGES BECAUSE OF 

FAILURE TO COMPLY WITH THE INSTALLATION 

AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING 

PAGES.  IF YOU REQUIRE ANY HELP OR HAVE ANY QUESTIONS 

RELATING TO THE 

INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL OUR 

TECHNICAL  SERVICE DEPARTMENT: 

800-766-5612 OR CUSTOMER SERVICE 1-888-640-4297 

HAVE THE INFORMATION LISTED BELOW BEFORE CALLING. 

WARNING 

BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY ADJUSTMENTS 

TO THE UNIT ALWAYS BE SURE MAIN CIRCUIT BREAKER IS OFF TO PREVENT DANGER 

OF SERIOUS ELECTRIC SHOCK. 

Model TWBS.EW.H 

Tempered Water Blending System 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

 

Содержание TWBS.EW.H

Страница 1: ... DESIGN OR STRUCTURE OF THE WATER HEATER HAS BEEN ALTERED IN ANY WAYWHATSOEVER THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES IF YOU REQUIRE ANY HELP OR HAVEANY QUESTIONS RELATINGTO THE INSTALLATION OR PERFORMANCE OF THIS HEATER PLEASE CALL OUR TECHNICAL SERVICE D...

Страница 2: ...with 45 90 psi 3 6 ATM flowing pressure at supply inlet Cold supply temperatures should range from 35 F to 75 F Where sediment or mineral content is a problem an inlet filter is recommended ELECTRICAL CONNECTIONS The unit requires 480 VAC 3 phase 60Hz power in a Delta configuration including three power leads and a ground conductor each sized for the system s maximum amperage of 24A The maximum po...

Страница 3: ...uts down the output from the heater On the cold water side we include a bypass valve Should the heater become blocked or the high limit shut off valve closes the bypass valve will open allowing the incoming cold water to bypass the system and proceed directly to the eyewash These two back up components permit the temperature level of the heated water to be maintained and permit the flow of cold wa...

Страница 4: ...licated chains of eyewashes long piping runs and recirculating loops should all be evaluated by a qualified engineer NOTE If for any reason the heater is starved of water while power remains on the unit may be damaged Also the heating elements only turn on under flow so any water within the heater will be subject to atmospheric conditions most of the time Therefore the heater should never be stati...

Страница 5: ...on the left Under no circumstances can these be changed Leave a minimum of 8 clearance above the unit to facilitate heating element replacement STEP 2 Flush supply piping thoroughly prior to connecting to inlet unions Connect outlet union to piping leading to eyewash Check for leaks Run water through the supply pipe to remove all debris from the pipe before connecting the heater Failure to do so c...

Страница 6: ... Carefully monitor initial few minutes of flow with hand in eyewash flow Check to ensure initial flow does not contain brief shots of hot water See troubleshooting if any problems IMPORTANT REPEAT TEST PROCEDURE WEEKLY THIS UNIT MUST NOT BE CONNECTED IN STAR CONFIGURATION WARNING FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY WARNING HAZARD OF ELECTRICAL SHOCK BEFORE BEGINNING ...

Страница 7: ...s not achieve desired temperature please call technical services TROUBLESHOOTING SYMPTOM NO HEAT INDICATOR LIGHT OFF 1 ELECTRIC SUPPLY IS OFF Turn on the main circuitbreaker 2 NO OR LOW WATER FLOW Ensure that the minimum flow rate to turn on your heater is met 0 95 GPM Also check that the inlet filter screen is clear from any debris 3 WATER CONNECTIONS ARE REVERSED Cold water inlet right side hot ...

Страница 8: ...nit is connected to the voltage supply specified on the rating label on the front cover of the unit and no other 3 ELEMENT BURNED OUT TURN OFF THE MAIN BREAKER Repeat the steps from paragraph 4 above 4 THERMOSTAT ADJUSTMENT SCREW NOT TURNED UP Turn the thermostat adjustment screw clockwise in small increments until the indicator light remains on Take care not to force the screw past its stop posit...

Страница 9: ...09 19 Model TWBS EW H Page 9 of 11 ...

Страница 10: ...09 19 Model TWBS EW H Page 10 of 11 ...

Страница 11: ...OOR USE ONLY 3 DIMENSIONS MAY VARY BY 1 2 12 7mm 15 1 4 387mm 2 USE TEFLON THREAD SEAL TAPE ON ALL WATER CONNECTIONS DO NOT USE PIPE DOPE APPROVED DRAWN PART NUMBER SCALE SHEET OF REVISION DRAWING TYPE SIZE A BY ECN NO PAGE DATE DATE ECN REVISED PER CHK D Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL ...

Отзывы: