background image

 

 

09/19 

Model TWBS.EW.H 

Page 5 of 11 

 

 

 

 

 

 

WATER SUPPLY 

 

The  minimum  recommended  supply  line  is  1/2"  IPS  COLD.    Cold  supply  temperatures  should 
range  from  35°F  to  75°F.  Outlet  connection  is  a  1/2"  NPT  dielectric  union.  We  recommend  a 
manual bypass loop with appropriate tamper resistant shut-off valves to allow for heater water 
system maintenance or service without interrupting emergency eyewash operation. 

 

 

INSTALLATION PROCEDURE... 

 
 

PROCEDURE 

 

Use Teflon thread seal tape on all water connections. 

Do not use pipe dope

. This unit 

should be mounted as close to the point-of-use as possible. 

 

STEP  1: 

Mount  unit  on  wall 

(This  unit  is  intended  for  indoor  use  only) 

per  attached 

installation drawing. Bolt dia. 

3/16” fasteners through heater box. Unit must be installed 

in the vertical only, with the inlet and outlet at the bottom. The cold water inlet is on the 
right  hand  side  and  the  hot  water  outlet  is  on  the  left.  Under  no  circumstances  can 
these  be  changed.  Leave  a  minimum  of 

8”  clearance  above  the  unit  to  facilitate 

heating element replacement. 

 

STEP 2: 

Flush supply piping thoroughly prior to connecting to inlet unions. Connect outlet union 
to  piping  leading  to  eyewash.  Check  for  leaks.  Run  water  through  the  supply  pipe  to 
remove  all  debris  from  the  pipe  before  connecting  the  heater:  Failure  to  do  so  could 
cause  damage  to  the  flow  switch.  Run  water  through  the  supply  pipe  to  remove  all 
debris  from  the  pipe  before  connecting  the  heater.  Failure  to  do  so  could  cause 
damage to the flow switch. 

 
 
 

 

 

 
               The  unit  should  be  installed  in  the  plumbing  system  in  such  a  way  that  there  is  no 

tendency  for  the  unit  to  be  starved  of  water.  For  example:  an  excessive  draw-off  of 
cold water just before the unit. Also, do not fit an unrestricted hot water draw-off point 
below the heater as this will tend to empty the heater by siphoning. 

 

 
 
 
 
 
 
 

NOTE 

ALL MOUNTING AND PLUMBING MUST BE COMPLETE BEFORE 

YOU PROCEED  WITH ELECTRICAL HOOK-UP. TEST THE 

INSTALLATION FOR LEAKS BEFORE  CONNECTING THE 

ELECTRICAL SUPPLY. 

Содержание TWBS.EW.H

Страница 1: ... DESIGN OR STRUCTURE OF THE WATER HEATER HAS BEEN ALTERED IN ANY WAYWHATSOEVER THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES IF YOU REQUIRE ANY HELP OR HAVEANY QUESTIONS RELATINGTO THE INSTALLATION OR PERFORMANCE OF THIS HEATER PLEASE CALL OUR TECHNICAL SERVICE D...

Страница 2: ...with 45 90 psi 3 6 ATM flowing pressure at supply inlet Cold supply temperatures should range from 35 F to 75 F Where sediment or mineral content is a problem an inlet filter is recommended ELECTRICAL CONNECTIONS The unit requires 480 VAC 3 phase 60Hz power in a Delta configuration including three power leads and a ground conductor each sized for the system s maximum amperage of 24A The maximum po...

Страница 3: ...uts down the output from the heater On the cold water side we include a bypass valve Should the heater become blocked or the high limit shut off valve closes the bypass valve will open allowing the incoming cold water to bypass the system and proceed directly to the eyewash These two back up components permit the temperature level of the heated water to be maintained and permit the flow of cold wa...

Страница 4: ...licated chains of eyewashes long piping runs and recirculating loops should all be evaluated by a qualified engineer NOTE If for any reason the heater is starved of water while power remains on the unit may be damaged Also the heating elements only turn on under flow so any water within the heater will be subject to atmospheric conditions most of the time Therefore the heater should never be stati...

Страница 5: ...on the left Under no circumstances can these be changed Leave a minimum of 8 clearance above the unit to facilitate heating element replacement STEP 2 Flush supply piping thoroughly prior to connecting to inlet unions Connect outlet union to piping leading to eyewash Check for leaks Run water through the supply pipe to remove all debris from the pipe before connecting the heater Failure to do so c...

Страница 6: ... Carefully monitor initial few minutes of flow with hand in eyewash flow Check to ensure initial flow does not contain brief shots of hot water See troubleshooting if any problems IMPORTANT REPEAT TEST PROCEDURE WEEKLY THIS UNIT MUST NOT BE CONNECTED IN STAR CONFIGURATION WARNING FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY WARNING HAZARD OF ELECTRICAL SHOCK BEFORE BEGINNING ...

Страница 7: ...s not achieve desired temperature please call technical services TROUBLESHOOTING SYMPTOM NO HEAT INDICATOR LIGHT OFF 1 ELECTRIC SUPPLY IS OFF Turn on the main circuitbreaker 2 NO OR LOW WATER FLOW Ensure that the minimum flow rate to turn on your heater is met 0 95 GPM Also check that the inlet filter screen is clear from any debris 3 WATER CONNECTIONS ARE REVERSED Cold water inlet right side hot ...

Страница 8: ...nit is connected to the voltage supply specified on the rating label on the front cover of the unit and no other 3 ELEMENT BURNED OUT TURN OFF THE MAIN BREAKER Repeat the steps from paragraph 4 above 4 THERMOSTAT ADJUSTMENT SCREW NOT TURNED UP Turn the thermostat adjustment screw clockwise in small increments until the indicator light remains on Take care not to force the screw past its stop posit...

Страница 9: ...09 19 Model TWBS EW H Page 9 of 11 ...

Страница 10: ...09 19 Model TWBS EW H Page 10 of 11 ...

Страница 11: ...OOR USE ONLY 3 DIMENSIONS MAY VARY BY 1 2 12 7mm 15 1 4 387mm 2 USE TEFLON THREAD SEAL TAPE ON ALL WATER CONNECTIONS DO NOT USE PIPE DOPE APPROVED DRAWN PART NUMBER SCALE SHEET OF REVISION DRAWING TYPE SIZE A BY ECN NO PAGE DATE DATE ECN REVISED PER CHK D Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL ...