18.9.2007
Rev. 2.4
Technical specifications
23
A=AIR-CONDENSED, W=WATER-CONDENSED
350=Muster 350, 800=Muster 800
A=3/N/PE
∼
400/230V 50Hz, B=
∼
250V 16A 50Hz, H=3/PE
∼
230V 50Hz, I=3/PE
∼
220V 60Hz, M=3/PE
∼
440V 60Hz
Item
Model
Type
Specification
Production in 24h, till
350
320 kg
Production in 24h, till
800
850 kg
Cooling system
350
A,W
Cooling system
800
A,W
Fluid refrigerant
350
R404A
Fluid refrigerant
800
R404A
Useable bin
350
T400-M350,Double Roller Bin M350
Useable bin
800
T400-M800
Standard voltage
350
220-240/1/50
Standard voltage
800
400/3N/50
Input power
350
2100 W
Input power
800
4600W
Water consumption
350
1 l/kg
Water consumption
800
1 l/kg
Size (WxDxH)
350
900x588x705 mm
Size (WxDxH)
800
1107x700x880 mm
Size (with packing) (WxDxH)
350
965x655x880 mm
Size (with packing) (WxDxH)
800
1210x800x1070 mm
Weight net
350
127 kg
Weight net
800
290 kg
Weight gross
350
150 kg
Weight gross
800
328 kg
Rerfrigerant R404A
A
350
800g
Rerfrigerant R404A
W
350
550g
Rerfrigerant R404A
A
800
1900g
Rerfrigerant R404A
W
800
1200g