blue’Log X series
51 | 120
10.3
Adding inverters
1.
Navigate to the "Devices" area via the top navigation bar.
2.
Navigate to the "Inverters" area via the left-hand navigation menu.
Fig. 35: Device websites: Adding a new inverter
3.
Select the manufacturer of your inverters (e.g. Kaco).
4.
Select the interface of the blue’Log data logger to which the inverter is connected
(e.g. RS485/422
–
1).
5.
By selecting "Start scan", the previously selected bus interface will be scanned for
connected inverters.
Fig. 36: Device websites: Inverter overview
6.
Once the scan is complete, the inverters found will be listed in the "Inverter
overview".
The inverters found are now known to the blue’Log data logger and will be
continuously queried.
With RS485/422 communication, only devices from one manufacturer
can be queried per connection / bus. Mixed operation is not possible.