blue’Log X series
23 | 120
6.
Interfaces
6.1
Power supply
The power supply of the data logger must comply with requirements below.
Power supply:
20 V DC, 4.0
A …
60 V DC, 1.3 A
max. 80 W
CAUTION
Complying with limit values
You should ensure that alternatively the following limit values are complied
with.
IEC 61010-1 (bzw. EN-/CSA-/UL- 61010-1)
Power supply of Limited-energy circuit with safety extra low voltage
(SELV)
EN 60950-1
Power supply with limited power sources
ATTENTION
Installing the power supply
The power supply including any protective devices may only be installed by
a qualified electrician.