10
OPERATION MANUAL
4. CONTROLS AND OPERATION.
E
A
B
C
D
A. Power Light - This light illuminates when the power is
turned on at the main isolating switch. (Fig. 7)
B. Start Button - The hydraulic pump motor is started when
this button is pressed (Fig. 7)
C. Stop Button - This button when pressed swiches off the
hydraulic pump. (Fig. 7)
D. Emergency Stop/RESET Button: Stops all machine
functions. Twist clockwise to reset. (Fig. 7)
E. Operating Lever - Moves the ram up or down (Fig. 8)
F. Pressure Gauge - Records the amount of pressure being
used. (Fig. 9)
G. Moving Head Handwheel - Moves the head right or left.
(Fig.10)
H. Moving Head Lock - Locks the head after it has been
moved. (Fig.10)
I. Tonnage Chart - Displays the tonnage at listed pressure
(Fig.11)
J’ Hand Pump Release - Releases the pressure in the hand
pump.
K. Hand Pump - Locks the main frame to the table.
(Fig.12)
F
G
H
J
K
I
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
4.1 CONTROLS