METAL-FACH
Heating Technology
5
Application
(User | Installer)
The boiler is designed to supply heat to central heating systems (radiators and floors) and to obtain domestic
hot water. The boiler should operate at its full rated power in a system with a buffer storing excess heat. The
figure shows an example of a boiler with a buffer. Boiler operation at nominal power allows for better fuel
utilization and better exhaust gas quality for the atmosphere . The correct operation and achievement of the full
capabilities of the boiler depends on the quality of the installation, appropriate chimney draft, and proper
operation and maintenance of the boiler.
Diagram of a boiler with a buffer
ATTENTION!
The boilers are designed for operation in open and closed water systems with gravity or
forced circulation, with security features compliant with the requirements of the
applicable PN-B-02413 standard for Heating and District heating and a closed system in
accordance with PN-EN 12828. Heating installations in buildings. Projects.
ATTENTION!
There must be an excess heat buffer in the heating system!