15. Technical Specifications
Voltage
V
230 (1
∼
50 Hz)
Current draw
A
8.3
Fuse protection
A
10 (time-lag)
Motor capacity (power input P1, S6 20% - 5 min)
kW
1.8
Protection class
IP
20
Degree of protection
II
Saw blade speed
min
-1
3400
Cutting speed
m/s
56
Saw blade diameter (outer)
mm
315
Arbor bore
mm
30
Dimensions
Machine in packing
−
Length x width x height
Machine ready to work, rotating table in 90
°
position, c/w dust extraction
port
−
Length x width x height (table saw mode)
−
Length x width x height (crosscut mode)
mm
mm
mm
795 x 595 x 452
575 x 700 x 415
575 x 700 x 730
Maximum work piece cross section
Standard cross cuts
−
Width x height
Mitre cuts (
rotating table
45
°
)
−
Width x height
Bevel cutss (track arm holder 45
° left
)
−
Width x height
Compound mitre cuts (
rotating table
45
°
/ track arm holder 48
° left
)
−
Width x height
mm
mm
mm
mm
170 x 100
118 x 100
170 x 67
62 x 62
Weight
Machine in packing
Machine ready to work
kg
kg
28.5
22.5
Permissible ambient temperature for operation
Permissible temperature for transport and storage
°
C
°
C
0 to +40
0 to +40
Noise emission according to Iso 61029–1**
Sound power level L
WA
−
no-load
−
when sawing
−
Uncertainty K
Sound pressure level (workplace) L
PA
−
no-load
−
when sawing
−
Uncertainty K
dB (A)
dB (A)
dB (A)
dB (A)
dB (A)
dB (A)
96.3
98.3
2.2
88.6
89.3
2.2
Effective value of weighted acceleration (vibration at handle)
Uncertainty K
m/s
2
m/s
2
< 2.5
1.5
Dust collector (not included in standard delivery)
−
Dust extraction port diameter
−
Minimum air volume flow
−
Minimum vacuum at dust extraction port
−
Minimum air speed at dust extraction port
mm
m
3
/h
Pa
m/s
43
550
740
20
* The motor reaches the stated power of 1800 watts at S6 20% 5 min. (intermittend periodic duty-type with starting). This means
that this saw can be operated for 1 minute at full-load rating (1800 watts) within a 5 minute operating period. The motor has to
deliver these 1800 watts only under extreme load conditions - during normal crosscutting it is subjected to much lower loads. With
lower loads the duty cycle of the motor increases substancially. Thus, when used as specified, because of its high reserve capacity,
overheating or overloading of the motor is not very likely to occur.
** The values stated are emission values and as such do not necessarily constitute values which are safe for the workplace.
Although there is a correlation between emission levels and environmental impact levels, whether further precautions are neces-
sary cannot be derived from this. Factors influencing the actually present environmental impact level in the workplace include the
characteristics of the work area and other noise sources, i.e. the number of machines and other neighbouring work processes.
Also, permissible workplace values may vary from country to country. This information is intended to assist the user in his estimate
of hazards and risks.