![Metabo HPT Strap-Tite NR3665DA Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/metabo-hpt/strap-tite-nr3665da/strap-tite-nr3665da_instruction-and-safety-manual_1776803024.webp)
24
English
METHODS OF OPERATION
This Nailer is equipped with the push lever and does not
operate unless the push lever is depressed.
There is a method of operation to drive nails with this
Nailer.
It is intermittent operation (Trigger
fi
re) only.
(Nailing operation indicator is light in blue.)
WARNING
●
Con
fi
rm that the nailing operation indicator is
lit in blue.
●
To avoid double
fi
ring or accidental
fi
ring due
to recoil.
1) Pull the trigger rapidly and
fi
rmly.
2)
Use the probe to ensure nails were
fi
red
accurately into the holes.
Set probe into the hole of the metal connector
securely with
fi
nger o
ff
the trigger.
Hole
Wood
Metal
connector
Probe
To operate the Nailer, hold perpendicular to the
workpiece.
Depress the push lever
fi
rmly until it is completely
depressed.
Pull the trigger to drive a nail.
Remove
fi
nger from the trigger and lift the tool o
ff
the workpiece completely.
To continue nailing in a separate location, move the
nailer along the metal connector, repeating steps
- as required.
NOTE
●
Operations and should be done within
2 seconds of each other. If more than 2 seconds
pass after , the Nailer will not work properly. If this
happens, retry from .
●
The push lever cannot be pressed all the way in
unless the Nailer is perpendicular to the workpiece.
Push lever
Trigger
Nailing operation indicator
(Light in blue)
WARNING
●
Keep your
fi
nger o
ff
the trigger except during
nailing operation, because serious injury
could result if the push lever accidentally
contacts you or others in work area.
●
Keep hands and body away from the
discharge area. This metabo HPT nailer may
bounce from the recoil of driving a nail and
unwanted subsequent nail may be driven,
possibly causing injury.
NOTE
●
If all warnings and instructions are followed, safe
operation is possible with all systems.
●
Always handle nails and package carefully. If nails
are dropped, collating bond may be broken, which
will cause mis-feeding and jamming.
●
After nailing:
1) remove battery from the Nailer;
2) remove all nails from the Nailer
000Book̲NR3665DA̲metabo.indb 24
000Book̲NR3665DA̲metabo.indb 24
2021/02/22 12:20:26
2021/02/22 12:20:26