21
English
□
Probe and Nail support (B) are surely mounted on
and no defect.
Probe
Nail support (B)
WARNING
Never look into the
fi
ring head.
(2) Installing the battery.
Do not operate the push lever or trigger while
installing the battery.
Battery
Push
Pull out
Insert
Handle
Latch
(3) Turn on the Power switch.
Power indicator
Power
switch
Nailing operation
indicator
Turn on the Power switch by push and hold on Power
switch more than 1 second.
Make sure the power indicator is lighting in green,
and nailing operation indicator is lighting in blue.
(FULL SEQUENTIAL ACTUATION MECHANISM,)
NOTE
●
Do not press the push lever and/or pull the trigger
during the process of turning the power switch ON.
Doing so will prevent the power switch from turning ON.
Light in blue
Light in green
[Auto power o
ff
]
When the power is turned on but the Nailer is not
used for 30 minutes, the Nailer is automatically
turned o
ff
. To turn on again, press the power switch.
WARNING
Never leave the Nailer with the power on. This
could result in an accident.
Nailing operation indicator
Lighting
(Blue):
FULL SEQUENTIAL ACTUATION MECHANISM,
Make sure the battery indicator is not blinking.
(page 26, Table 5)
If the battery indicator is blinking, the battery doesn’t
have enough power and it needs to be charged.
(4) Remove the
fi
nger from the trigger and press the
push lever against the workpiece with pulling back
the feeder knob.
□
THE NAILER MUST NOT OPERATE.
Depress
push lever
Do not pull
the trigger
Pulling back
feeder knob
(5) Separate the push lever from the workpiece.
Next, point the nailer downward, with pulling back
the feeder knob, pull the trigger and then wait in that
position for 5 seconds or longer.
000Book̲NR3665DA̲metabo.indb 21
000Book̲NR3665DA̲metabo.indb 21
2021/02/22 12:20:25
2021/02/22 12:20:25