14
GB
IRL
AUS
USA
NZ
CDN
IND
Checks
Visual inspection:
Are tank [1], pump [2], hose [3], shut-off valve [4] and spray wand [8]
with nozzle [16] undamaged?
(Figures 1, 3, 18)
Pay special attention to the connections between the tank – hose and the hose – shut-
off valve and to the condition of the pump threading and spray wand.
No leaks:
Pump up the empty device to 2 bar
(Fig. 10)
.
►
The pressure must not decrease more than 0.5 bar within 30 minutes.
Function:
Pull up the piston pressure gauge [10]
(Fig. 4)
►
The pressure must dissipate.
Activate the shut-off valve [4]
(Fig. 12)
►
The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
Making preparations
Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the piston pressure gauge [10] until all excess pressure is
released from the tank
(Fig. 4)
2. Press the piston rod with handle [11] down and turn it counterclockwise
►
The piston rod with handle is locked.
(Fig. 5)
3. Unscrew the pump [2] from the tank.
(Fig. 6)
We recommend you mix the spraying liquid in the device or premix it in an external
tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until
full.
4. Add the spraying liquid to the tank [1]
(Fig. 7)
5. Check the filling level with the scale [12] on the tank.
(Fig. 7)
6. Screw the pump [2] into the tank.
(Fig. 8)
7. Press the piston rod with handle [11] down and turn it counterclockwise.
(Fig. 9)
►
The piston rod with handle is unlocked.
(Fig. 9)
8. Generate the desired pressure (
→
Table 2)
in the tank
(Fig. 10)
.
The maximum pressure should not exceed 3 bar (red line on the piston pressure gauge,
Fig. 10). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
9. Press the piston rod with handle [11] down and turn it counterclockwise
(Fig. 5)
►
The piston rod with handle is locked.