7 VG9H 70 en
5
1.5
Technical specifications
VG9000H INTELLIGENT SAFETY SOLENOID
General
Loop powered, no external power supply required.
Suitable for rotary and sliding-stem valves.
Actuator connections in accordance with VDI/VDE 3845
and IEC 60534-6 standards.
Action:
Double or single acting
Travel range:
Linear: 10–120 mm
Rotary: 45–95°
Measurement range 110° with freely
rotating feedback shaft
Environmental influence
Standard temperature range:
-40°...+85 °C / -40° to +185 °F
Influence of temperature on valve position:
< 0.5 % / 10 °C
Influence of vibration on valve position
No effect when measured inpulse
2g 5–150 Hz, 1g 150–300 Hz,
0.5g 300–2000 Hz.
No effect on PST if max. response 4g
measured at housing.
No unintended valve movements if max.
response 15g measured at housing
Enclosure
Material (VG92_):
Epoxy coated anodised aluminium
alloy, glass window (excluding E2)
Material (VG93_):
Stainless steel (316 or equivalent),
glass window as an option
Mechanical position indicator and LUI visible through the
main cover (VG92_)
Protection class:
IP66, NEMA 4X
Pneumatic ports:
VG9_1_
1/4 NPT
VG9235
1/2 NPT
VG9237
1 NPT (1/2 NPT supply)
(single acting only)
Conduit entry thread:
M20 x 1.5 or 1/2" NPT (VG9_U_ or
VG9_E2_)
Weight:
VG921_
3.0 kg / 6.6 lb
VG9235
4.6 kg / 10.1 lb
VG9237
5.0 kg / 11 lb
VG931_
9.0 kg / 19.8 lb
VG92_ with extension housing plus 1.0 kg / 2.2 lb
VG93_ with extension housing plus 3.0 kg / 6.6 lb
Pneumatics
Spool material:
Hard anodized aluminium with
special teflon coating
Supply pressure:
3.0–7.5 bar / 44–109 psi
Output pressure:
3.0–7.5 bar / 44–109 psi
Air quality:
According to ISO 8573-1:2001
Solid particles: Class 6
Humidity: Class 1
(dew point 10 °C / 18 °F below minimum
temperature is recommended)
Oil class: 3 (or <1 ppm)
Capacity with 4 bar / 60 psi supply:
VG9_12
7 Nm3/h / 4.1 scfm (Cv = 0.06)
VG9_15
90 Nm
3
/h / 53 scfm (Cv = 0.7)
VG9235
380 Nm
3
/h / 223 scfm (Cv = 3.2)
VG9237
feed 380 Nm
3
/h / 223 scfm (Cv = 3.2)
exhaust 700 Nm
3
/h / 412 scfm (Cv = 6.4)
Consumption with 4 bar / 60 psi supply (VG9000H):
actuator pressurized 0.22 Nm
3
/h /
0.13 scfm,
actuator vented 0.25 Nm
3
/h / 0.15 scfm
Consumption with 4 bar / 60 psi supply (VG9000H_P):
0.25 Nm
3
/h / 0.15 scfm
Electronics (input)
Electrical connections: 0.25–2.5 mm
2
Supply power:
Loop powered, 4–20 mA
Signal range:
3.7–22 mA
Signal details (VG9000H):
0.0–3.7 mA (trip state,
diagnostics not available)
3.7–6.0 mA (trip state,
diagnostics available)
6.0–16.0 mA (hysteresis range)
16.0–22.0 mA (normal state,
diagnostics available
Signal details (VG9000H_L3):
0.0–7.7 mA (trip state,
diagnostics not available)
7.7–10.0 mA (trip state,
diagnostics available)
10.0–16.0 mA (hysteresis range)
16.0–22.0 mA (normal state,
diagnostics available)
Signal details (VG9000H_P):
0.0–3.7 mA (de-energized state,
diagnostics not available)
3.7–6.0 mA (normal state,
diagnostics available)
6.0–8.0 mA (normal state,
PST available)
8.0–22.0 mA (normal state, PST and
calibration available)
Load voltage:
up to 9.7 V DC / 20 mA
(corresponding 485 Ω)
Voltage: max
30
V
DC
Polarity protection: -30 V DC
Over current protection:
active over 35 mA
NOTE:
There may have two identification plates, if there is double
approval (VG9_XE6_) asked. When the device is installed,
remove the identification plate which is not valid. If device
is installed to Ex d area, it can't be installed to Ex i area any-
more even if identification plate is changed.
Ex NOTE:
This manual contains technical specifications for sev-
eral types of the ValvGuard. If in doubt, refer to the
type approval certificate of the respective version.
The certificate is delivered with the field device and is also
available from the manufacturer.