14
Visual inspection:
$UHWDQN>@SXPS>@DQGKRVH>@XQGDPDJHG"
(Fig. 1)
+
3D\VSHFLDODWWHQWLRQWRWKHFRQQHFWLRQVEHWZHHQWKHWDQN±KRVHDQGWRWKHFRQGLWLRQ
of the pump thread and hose.
No leaks:
3XPSXSWKHHPSW\GHYLFHWREDU
Ź7KHSUHVVXUHPXVWQRWGHFUHDVHPRUHWKDQEDUZLWKLQPLQXWHV
Function:
3XOOWKHUHGEXWWRQRQWKHVDIHW\YDOYH>@
(Fig. 3)
Ź7KHSUHVVXUHPXVWGLVVLSDWH
6FUHZWKHKRVH>@WLJKWO\LQWRWKHRXWOHWSRUW>@
(Fig. 2)
+
Note the location of the spigot [8] in order to be able to insert the lock.
,QVHUWWKHORFN>@
(Fig. 2)
Ź7KHORFNFORVHVDQGWKHKRVHLVVHFXUHGIURPXQVFUHZLQJRXWRIWKHWDQN
EN ENGLISH
Assembly
Checks
+DYHGDPDJHGSDUWVRUSDUWVWKDWGRQRWZRUNSURSHUO\UHSDLUHGLPPHGLDWHO\E\RXU
FXVWRPHUVHUYLFHGHSDUWPHQWRUE\VHUYLFHSDUWQHUVDXWKRUL]HGE\XV
7DQN>@ZLWKSXPS>@DQGVSDUHSDUWVSRXFK>@LQVWUXFWLRQVIRUXVH>@KRVH>@SXPS
KROGHU>@
(Fig. 1)
Device
3585W
3615W
0D[¿OOLQJDPRXQW
10 l
10 l
Total contents
13 l
13 l
0D[RSHUDWLQJSUHVVXUH
6 bar (88 psi)
0D[RSHUDWLQJWHPSHUD¤WXUH
50 °C (122 °F)
:HLJKWZKHQHPSW\*URVVZHLJKWPD[
NJ
NJ
0DWHULDORIWDQN
6WHHOZLWKSRO\HVWHUFRDWLQJ
Stainless steel
7HFKQLFDOUHVLGXDOTXDQWLW\
O
Scope of delivery
Technical data
Table 1
+
<RXZLOO¿QGWKHLOOXVWUDWLRQVUHIHUUHGWRDERYHLQWKHSDJHV±RIWKHVH