HDM97Pocket Quick Reference

 

 

\\

  

6

www.ibpmedical.com

Press 3 seconds

Versions 

The HDM97Pocket meters are equipped with up to 5 channels, depending on the version. 

Channel  

HDM97BL     HDM97BH           HDM97BN      HDM97BO      HDM97BP      HDM97BQ

Conductivity    

Temperature    

Timer    

Pressure    

pH 

Flow 

 

Operating 

The functions of the keys are structured hierarchically from left to right. 

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CD/TEMP

(Available in versions BN, BO, BP and BQ)

Returns automatically back to measuring mode after 5 sec.

Selection of conductivity temperature coefficient

Reading min. Value

Reading max. Value

Reset of both the min. And max. Value
Return to measuring mode

ESC

F

F

Channel Select

No function

TEMP

F

(Available in versions bn, bo, bp and bq, if enabled in the basic settings)

Selection between units °c or °f

Returns automatically back to measuring mode after 5 sec.

Reading min. Value

Reading max. Value

F

Reset of both the min. And max. Value
Return to measuring mode

ESC

No function

PRES

F

(Only available in versions bm, bh, bo, bp and bq)

Selection between units mmhg, mbar, kpa and psi

Pressure drop measurement

OK

ESC

Start countdown timer

Return to measuring mode

F

Reading min. Value

F

Reading max. Value

Returns automatically back to measuring mode after 5 sec.

Reset of both the min. And max. Value

ESC

Return to measuring display

Tare (shown with “zero” in display afterwards)

Содержание IBP HDM97Pocket Series

Страница 1: ...M97BO HDM97BP HDM97BQ This document describes the major functions of the HDM97Pocket instrument series The complete manual can be found at http www ibpmt com medical_e meter_documents shtm and on the...

Страница 2: ...tic discharge on the connectors This can lead to substantial damage of the instrument Make sure to be completely discharged before touching the connectors or cables connected to the instrument Adjust...

Страница 3: ...USB connector is mounted on the right side of the instrument It is implemented as a Mini USB A receptacle The current consumption of the HDM97Pocket all versions can be up to 500 mA while charging the...

Страница 4: ...P BQ Target time adjustment for pressure holt test PHT TIMER All Enables disables the stopwatch function Flow BL BQ Enables disables the Flow channel pH BP enables disables the pH channel TEMP BN BO B...

Страница 5: ...and save setting or to discard this setting FLOW OK Only availble with version BQ ON OFF FLOW enabled FLOW disabled OK ESC Then to apply and save setting or to discard this setting TEMP OK Only avail...

Страница 6: ...alue Reset of both the min And max Value Return to measuring mode ESC F F Channel Select No function TEMP F Available in versions bn bo bp and bq if enabled in the basic settings Selection between uni...

Страница 7: ...x Value ESC Return to measuring display Reset accumulated volume to 0 Timer If enabled in the Basic Settings OK OK OK Afterwards Afterwards Timer Timer Timer The cycle start stop and reset can start a...

Страница 8: ...n pass off through the outlet For immersion usage the probe must be unscrewed from the flow through adapter To accomplish that do not turn the upper shank the probe may be damaged Only turn the nut as...

Отзывы: