HDM97Pocket Reference Meter Series 

Safety Instructions and Quick Start Guide 

HDM97BL HDM97BH HDM97BN HDM97BO HDM97BP HDM97BQ

This document describes the major functions of the HDM97Pocket instrument series. The complete manual can 
be found at http://www.ibpmt.com/medical_e/meter_documents.shtm and on the installation CD. For reading 
the document Adobe

®

 PDF it’s necessary to have Adobe

®

 PDF Reader installed. Adobe

®

 Reader for Microsoft

®

 

Windows

®

 is included in several language versions on the CD. 

 

 

 

 

HDM97

Pocket

 

 Reference Meter Series 

 

Safety Instructions and Quick Start Guide 

 

HDM97

BL

    

HDM97

BM&BH

    

HDM97

BN    

HDM97

BO

   HDM97

BP    

HDM97

BQ

     

        

   

 

This  document  describes  the  major  functions  of  the  HDM97

Pocket

  instrument  series.  The  complete  manual 

can  be  found  at  http://www.ibpmt.com/medical_e/meter_documents.shtm  and  on  the  installation  CD.  For 

reading the document Adobe

®

 PDF it's necessary to have Adobe

®

 PDF Reader installed. Adobe

®

 Reader for 

Microsoft

®

 Windows

®

 is included in several language versions on the CD. 

 

 

 

 

                    

 

 

 

 

 

 

Display 

Reset / Tare pressure / Adjust (pH) 

and navigation key 

  "OK" 

Special functions 

and navigation key 

 "next"

 

Select functions 

and navigation key 

 "previous"

 

ON / OFF 

For OFF press 3 sec. 

Channel select 

and navigation key 

  "ESCAPE" 

Display

Reset / tare pressure / adjust (pH)
and navigation key “OK”

Special functions and navigation key              
“next”
Select functions and navigation key 
“previous”

ON / OFF
For OFF press 3 sec.

Channel select
and navigation key “ESCAPE”

Содержание IBP HDM97Pocket Series

Страница 1: ...M97BO HDM97BP HDM97BQ This document describes the major functions of the HDM97Pocket instrument series The complete manual can be found at http www ibpmt com medical_e meter_documents shtm and on the...

Страница 2: ...tic discharge on the connectors This can lead to substantial damage of the instrument Make sure to be completely discharged before touching the connectors or cables connected to the instrument Adjust...

Страница 3: ...USB connector is mounted on the right side of the instrument It is implemented as a Mini USB A receptacle The current consumption of the HDM97Pocket all versions can be up to 500 mA while charging the...

Страница 4: ...P BQ Target time adjustment for pressure holt test PHT TIMER All Enables disables the stopwatch function Flow BL BQ Enables disables the Flow channel pH BP enables disables the pH channel TEMP BN BO B...

Страница 5: ...and save setting or to discard this setting FLOW OK Only availble with version BQ ON OFF FLOW enabled FLOW disabled OK ESC Then to apply and save setting or to discard this setting TEMP OK Only avail...

Страница 6: ...alue Reset of both the min And max Value Return to measuring mode ESC F F Channel Select No function TEMP F Available in versions bn bo bp and bq if enabled in the basic settings Selection between uni...

Страница 7: ...x Value ESC Return to measuring display Reset accumulated volume to 0 Timer If enabled in the Basic Settings OK OK OK Afterwards Afterwards Timer Timer Timer The cycle start stop and reset can start a...

Страница 8: ...n pass off through the outlet For immersion usage the probe must be unscrewed from the flow through adapter To accomplish that do not turn the upper shank the probe may be damaged Only turn the nut as...

Отзывы: