28
After wiring the device, switch on the bus
voltage.
Automatic recognition:
Choose the menu option "New function" or
"Edit function" in the Easy base unit.
The device is automatically recognised by
the base unit and displayed in the channel
list with the allocated device number.
Manual recognition:
If the device is no longer in the delivery sta-
tus, you should press the programming
key
briefly
(< 2 seconds) for recognition.
The red LED lights up during the recogni-
tion process.
Start-up with the Easy base unit
Anleitung_764291.book Seite 28 Dienstag, 15. Oktober 2002 10:55 10
29
The device is recognised by the base unit
and displayed in the channel list with the
allocated device number.
Start-up:
If the device has been recognised, the
channel of the device appears in the chan-
nel overview of the Easy base unit.
The top/left or bottom/right of the push-
button can be pressed to connect (select)
the push-button channel. The channel of
the device is marked in the channel over-
view.
The programming key can be pressed for
longer (> 2 seconds) in order to connect
(select) the shutter actuator channel.
Further information can be found in the op-
erating instructions for the Easy base unit
or in the relevant documents for other ex-
ternal EIB Easy setting devices.
Behaviour when bus voltage is estab-
lished/returns
The push-button is ready for use 17 s after
the bus voltage has returned.
Behaviour when bus voltage fails
The drive is switched off.
Anleitung_764291.book Seite 29 Dienstag, 15. Oktober 2002 10:55 10
30
Adjustable parameters
(adjustable on base unit)
Functions
Alarm mode
(e. g. wind alarm)
1)
Factory setting
none
1)
Switching
Dimming
Blind
no alarm
1)
Up
Down