22
Note
If there is no signal from the relevant
sen-sor (e.g. wind sensor) within a cy-
cle time of 30 min, the drive again
moves into the safe position and stays
there until the sensor unlocks the blind
function again.
The following safety functions can be set
on the base unit:
- No alarm
- Up
- Down
Note
The factory setting is the "No alarm"
function.
The sensor (push-button 1-fold) has sever-
al functions to choose from, the settings
for which can be made on the base unit. If
the sensor is operated with the shutter ac-
tuator, the "Blind" function is automatically
selected. If you use the sensor to control a
switching actuator, for example, the
"Switching" function is automatically im-
plemented.
Sensor component
Anleitung_764291.book Seite 22 Dienstag, 15. Oktober 2002 10:55 10
23
- Switching
Switch on by pressing top/left of push-but-
ton. Switch off by pressing bottom/right of
push-button.
Note
The red LED (status indicator) on the
push-button 1-fold is on while the actu-
ator is enabled.
- Dimming
Switch on by briefly pressing top/left of
push-button (< 0.8 s).
Switch off by briefly pressing bottom/right
of push-button (< 0.8 s).
Increase light by pressing top/left of push-
button for longer (> 0.8 s).
Decrease light by pressing bottom/right of
push-button for longer (> 0.8 s).
Note
The red LED (status indicator) on the
push-button 1-fold is on while the actu-
ator is enabled.
- Blind
Open blind by pressing top/left of push-
button for longer (> 0.8 s).
By briefly pressing top/left of push-button
(< 0.8 s), the blind stops opening, or the
slats are opened one by one.
Anleitung_764291.book Seite 23 Dienstag, 15. Oktober 2002 10:55 10
24
Close blind by pressing bottom/right of
push-button for longer (> 0.8 s).
By briefly pressing bottom/right of push-
button (< 0.8 s), the blind stops closing, or
the slats are closed one by one.
Electrical connection
Caution
The switch outputs have a bistable relay.
Strong vibrations during transportation can
cause the switching contacts of the out-
puts to change to the switched-on state.
When connecting to the mains, the outputs
may contain a voltage!
Note
The ambient temperature should be
observed, see "technical data".
Installation
Anleitung_764291.book Seite 24 Dienstag, 15. Oktober 2002 10:55 10