1. Terminal Block:
used for external accessories (see chart below).
NOTE:
The terminal block is weather protected by a rubber grommet.
When using external wiring, the cable holes can be punched through with a small screwdriver. These holes
should be sealed with silicon sealant in order to maintain the weather proof rating.
2. DN Button:
used to drive door DOWN.
3. UP Button:
used to drive door UP.
4. P Button:
used to “PROGRAM” the DOOR LIMITS.
5. S Button:
used to “SAVE” the “REMOTE CONTROLS”.
6. Key Lock:
used to lock the engage/disengage mechanisim for commercial applications.
7. LEDs:
1. Program DOWN, and Diagnostic code indicator Number 1.
2. Program UP indicator.
3. Diagnostic code indicator Number 2.
8. Courtesy Light:
turns on during operation and automatically turns off after 3 minutes.
No
Function
Colour Polarity
Comment
1
Push button
Red
+ve
Dry contact input for push button wired wall controls:
2
Common
White
-ve
Common terminal for push button, IR Beams & accessory
power:
3
IR Beams
Grey
+ve
IR Beam Input: (pulsing type only)
4
Accessory Power
Green
+ve
24v dc 50 mA accessory output available for a universal
receiver (output not active in Low Standby mode)
CONTROL PANEL
7