3
QUICK REFERENCE GUIDE
ADJUST THE TRAVEL DISTANCE
6
1. Release the opener manual release with the release key, see section 9.
2. From a complete closed position, remove the cover (A in figure 1).
3. For right hand installation release screw D and adjust the position of the
hardstop C to touch the arm. Tighten the screw when required position of
the hardstop is reached.
4. Manually move the gate to the required complete open position.
5. Release screw E and move the hardstop B to the position where the arm is
touched. Tighten the screw when the required hardstop position is reached.
6. Put the cover in its original position and secure with the screw.
7. Re-engage the manual release mechanism.
The internal hardstops can be replaced the external hardstops of the gate or a combination of both can be used depending on
installation situation and requirements.
A
B
C
E
D
13 mm
13 mm
figure 1
CONTROL BOARD AND OPENER CONNECTION
7
The control board is already pre-installed in the Primary opener and pre-wired
to the MOTOR1 terminals.
To gain access to the control board in the Primary opener, remove the 2
screws to the back of the cover and then remove the 2 screws on the sides
(figure 1). The terminals for wiring accessories are directly accessible. To get
access to the programming buttons remove the transparent plastic cover
(figure 2) and place it back once programming is finished. Remove the cover of
the Secondary opener, same way as with the Primary opener to gain access to
the opener wiring terminal (figure 3).
NOTE: As per the default settings, the Primary opener is considered
installed on the left (when looking from inside out), and the Secondary
opener on the right.
In case the Primary is installed on the right, and the Secondary opener on
the left, change the motor directions for both units in the Motor Direction
Programming section.
8.8.
4 mm
Primary Opener
Secondary Opener
Extension cable
(not supplied)
8.8.
4 mm
Primary Opener
Secondary Opener
Extension cable
(not supplied)
8.8.
4 mm
Primary Opener
Secondary Opener
Extension cable
(not supplied)
figure 1
figure 2
figure 3
OPENER CONNECTION
8
NOTE: The opener wired to the MOTOR1 terminal, will always open first and close last.
The Primary opener is already pre-wired to MOTOR1 terminals. No extra steps required for
MOTOR1 wiring.
NOTE: The opener wired to MOTOR2 terminal, will always open last and close first.
Connect the extension cable (not provided) to the wiring terminals of the Secondary opener.
The cable colours of the Secondary opener should match the control board wiring terminal for
MOTOR2.
1. Feed the Secondary opener extension cable through one of the cable glands at the bottom
of the Primary opener. Ensure that the cables will not be cut by the opener of the arm during operation.
2. Connect the Secondary opener cables to the MOTOR2 terminals as follows:
• Red cable to RED terminal
• Green cable to GRN terminal
• White cable to WHT terminal.
Power Wiring
3. Connect the pre-assembled mains power plug to the nearby general purpose
power outlet.
4. Tighten the IP rated gland.
Power Wiring
Mains power wiring must
be done by a certified
electrician.