REPLACEMENT PARTS

If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons
in order to avoid hazard.

Power Cord
026B0181

041A4004
Passpoint
Assembly

041A4024
Transformer

041A0005
Logic Board / PCB Housing / Control Cover (assembly)

041A0007
LED Module

041A1805
Lens Cover

041A4033
Motor Assembly

041A4023-1
Power Board

041A1804-1
Brand Cover

041A0010
Chassis Cover

RAIL REPLACEMENT PARTS

041A4017-1

Motor shaft adapter

041A4021R

Trolley latch (belt)

041A4016R

Position tab (belt)

33

Содержание MS65MYQ

Страница 1: ...ference MS65MYQ Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY go...

Страница 2: ...alified persons in order to avoid hazard This opener should not be installed in a damp or wet space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors a...

Страница 3: ...ce supported entirely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If yo...

Страница 4: ...ton contains the opener its fitting hardware and accessories The rail carton contains the rail and some hardware Rails Different length rails 2 2 m 2 4 m are available for different height doors ensur...

Страница 5: ...procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 10 4x 9 8x 8 4x 7 1x 6 1x 1 1x 2 1x 3 4x 4 4x 5 4x HARDWARE PROV...

Страница 6: ...where built in pedestrian doors are installed within a garage door Terminals 4 5 are normally linked If the link is removed the opener will not operate Remove the link and install a Safety switch to...

Страница 7: ...tightening to compress the spring and remove all the slack in the belt DO NOT OVERTIGHTEN but ensure belt is firm 3 36 38 mm as indicated in the diagram is normal 3 4 2 A 1 5 1 Slide the RAIL BRACKET...

Страница 8: ...w the header bracket Use foam packing material as a protective base NOTE If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rai...

Страница 9: ...etween door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively par...

Страница 10: ...Item 4 in Hardware Provided Section 5 HANG THE OPENER 14 The opener must be securely fastened to a sound structural support above the opener 1 Postion the opener as in the previous step Check the rail...

Страница 11: ...see figure 3 Unscrew the front two screws in the trolley assembly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL RELEASE The...

Страница 12: ...door is in the desired UP position press and release the PROG Button The DOWN Arrow Button will begin to flash figure 4 4 Press and hold the DOWN Arrow Button until the door is in the desired DOWN po...

Страница 13: ...ry from a closing garage door Repeat test once a month and adjust as needed 19 Low Standby Mode sub 1 watt is activated by the factory to deliver the lowest possible standby power In this mode the Ext...

Страница 14: ...ng section THE PROTECTOR SYSTEMTM OPTIONAL To prevent entrapment install The Protector System no higher than 100 mm above the floor Disconnect power to the garage door opener before installing The Pro...

Страница 15: ...n Keep clear of the IR Beams and check the door closes after the preset time To Deactivate TTC 1 Enter into TTC Activation mode by pressing both PROG and DOWN buttons together for 3 seconds figure 2 R...

Страница 16: ...gether for 3 seconds figure 3 The Courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all remote control codes as in the Wireless programming section will also delete...

Страница 17: ...LEARN button on the garage door opener 2 Press and release the yellow LEARN button The LED indicator light will glow steadily 3 Enter a 4 digit personal identification number PIN of your choice on th...

Страница 18: ...door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary...

Страница 19: ...m 041A4036 Centre Rail bracket RAIL HARDWARE 32 18 ACCESSORIES 6 5 7 4 760E E1702M 774ANZ 8 9 3 1 2 10 827AU 1 Model E138M Wireless wall button 2 Model E960M 4 Channel remote control 3 Model E940M 1 C...

Страница 20: ...er Cord 026B0181 041A4004 Passpoint Assembly 041A4024 Transformer 041A0005 Logic Board PCB Housing Control Cover assembly 041A0007 LED Module 041A1805 Lens Cover 041A4033 Motor Assembly 041A4023 1 Pow...

Страница 21: ...older installations especially on excessively heavy doors check the Motor Shaft Adapter has not stripped 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic c...

Страница 22: ...ded Safety sensors are misaligned or were momentarily obstructed Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would i...

Страница 23: ...ty reverse in both UP and DOWN direction Electronic Automatic force adjustment Electrical Transformer overload protector and low voltage push button wiring Limit Device Mechanical Passpoint RPM sensor...