TEST THE SAFETY REVERSE SYSTEM
Procedure:
With door opened place a 40 mm obstacle (1)
laid flat on the floor under the garage door. Operate the
door in the down direction. The door must reverse off the
obstacle. If the door stops on the obstacle, remove obstacle
and repeat Program the Limits and Force Steps, then
repeat safety reverse test.
When the door reverses off the 40 mm obstacle, remove
the obstacle and run the opener through a complete travel
cycle. Door must not reverse in closed position. If it does,
repeat Program the Limits and Force then repeat safety
reverse test.
1
40 mm high
The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle
laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing
garage door. Repeat test once a month and adjust as needed.
19
Low Standby Mode (sub 1 watt) is activated by the factory to deliver the lowest possible standby power.
In this mode the External Accessories Power and the IR Beams are turned OFF when the door is closed and the courtesy light
is OFF.
The Normal Standby Mode will need to be activated for External Accessories Power.
To Activate Normal Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the
UP
and
DOWN
arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 10 flashes.
Release the arrow buttons.
To Activate Low Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the
UP
and
DOWN
arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 1 flash.
Release the arrow buttons.
PROGRAM THE LOW STANDBY MODE (OPTIONAL)
20
Indicator LED