background image

44

Australia 

 

Phone toll free 1800 474 326  
Fax toll free 1800 888 121  
Unit 1, 75 Epping Road North Ryde, NSW 2113

Website www.gomerlin.com.au 

Email [email protected] 

New Zealand 

 

Auckland phone 09 477 2823  
Phone toll free 0800 653 667  
Fax toll free 0800 653 663 

Website www.gomerlin.co.nz

CHAMBERLAIN LIMITED WARRANTY 

Merlin® Professional Swing L 300 

Linear Atuator Gate Opener

Chamberlain Australia Pty Limited / Chamberlain New Zealand Limited 

(Chamberlain),

 the manufacturer of Merlin® automatic gate openers, is committed to manufacturing 

and supplying high quality goods. As part of this commitment, we seek to provide reliable service 

and support for our goods and are pleased to provide you, the original purchaser, with this 

Chamberlain Limited Warranty. 

The benefits given to you under this Chamberlain Limited Warranty are in addition to any rights and 

remedies that you may have under Australian or New Zealand consumer protection laws. Our goods 

come with guarantees that cannot be excluded under the Australian Consumer Law, or New Zealand 

Consumer Guarantess Act 1993. You are entitled to a replacement or refund for a major failure and 

for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have 

the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not 

amount to a major failure.

Chamberlain’s warranty

What is covered

Chamberlain warrants to the original purchaser of the Merlin Swing L 300 Linear Actuator Gate 

Opener (Unit) that all parts of the Unit, other than remote controlled transmitters, battery back up 

units, accessories, globes and batteries, are free from defects in materials and workmanship for a 

period of 36 months or 7,500 cycles (each opening & closing of the gate equals 1 cycle) whichever 

comes first, from the date of purchase when installed by a Professional dealer appointed or 

authorised by Chamberlain on a typical gate installation within the indicated specifications.

Chamberlain warrants that the remote controlled transmitters (E970M) included with the Unit are free 

from defects in materials and workmanship for a period of 24 months from the date of purchase and 

all other accessories included with the Unit are free from defects in materials and workmanship for a 

period of 12 months from the date of purchase.

What is not covered

 

Batteries and globes are not covered under the Chamberlain Limited Warranty. 

Travel costs incurred by Chamberlain or the Professional Dealer in either travelling to or from areas 

outside a capital city metropolitan area. These costs will be at the purchaser’s expense. 

Additional access costs incurred by a Professional Dealer or Chamberlain in obtaining access where 

the Unit is not readily accessible. These cost will be at the purchaser’s expense.

Warranty Conditions

 

It is a condition of this Chamberlain Limited Warranty that the Unit is sold, installed and serviced by a 

Professional Dealer appointed or authorised by Chamberlain. A Merlin branded gate opener 

purchased over the internet and installed by a person other than a Professional Dealer will not be 

covered by this Chamberlain Limited Warranty.

It is also a condition of this Chamberlain Limited Warranty that for the operating life of the Unit: 

1 the gate and the Unit is professionally maintained and serviced by a Professional Dealer during the  

   Chamberlain Limited Warranty period such that the gate operates according to manufacturer 

   specifications. If your gate binds or sticks, then it must not be  used until serviced by a trained 

   gate technician or Profesional Dealer. The gate service fee will be at the purchaser’s expense;

2 the warranty is registered by completing the online form at

   www.gomerlin.com.au or www.gomerlin.co.nz; and

3 you retain your sales docket or invoice as proof of purchase, and attach it to this manual to enable   

   you to establish the date of purchase in the unlikely event of a warranty service being required.

Making a claim

 

During the applicable Chamberlain Limited Warranty period, if you are concerned that the Unit may 

be defective, call the Professional Dealer that sold/installed the opener, or our service centre on the 

toll free number below and a Chamberlain technician will diagnose the problem and arrange for this 

to be rectified. 

Once the problem has been diagnosed, subject to your rights under the applicable Australian and 

New Zealand consumer protection laws with respect to major failures, Chamberlain or its 

Professional Dealer will provide you with either, repairs to the Unit or a replacement Unit.Repairs and 

replacement parts provided under this Chamberlain Limited Warranty are provided free of charge 

and are warranted for the remaining portion of the original warranty period.

This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and 

remedies as a consumer.

Exclusions - what voids the warranty 

If our service centre determines that a warranty claim has been made in respect of a failure or defect 

arising under or out of any exclusion detailed below such that the claim is not covered under this 

Chamberlain Limited Warranty, we may, subject to your other rights and remedies as a consumer, 

charge you a fee to repair, replace and/or return the Unit to you.

This Chamberlain Limited Warranty does not cover any failure of, or defect in, the Unit due to: 

1  non-compliance with the instructions regarding specifications, installation, operation, maintenance 

    and testing of the Unit or of any product with which the Unit is used; 

2  any attempt by a person other than a Professional Dealer to repair, dismantle, reinstall or move 

    the Unit to another location once it has been installed;

3  use of any copy, imitation or replica gate opener remotes with your Merlin Unit; 

4  tampering, neglect, abuse, wear and tear, accident, electrical storm, excessive use or conditions  

    other than normal use; 

5  problems with, or relating to, the gate or gate hardware;

6  problems caused by electrical faults or replacement of batteries or light bulbs, blown fuses, 

    electrical surges, power surges or power strikes, fire, flood, lightning or storms;

7   corrosion caused by sea air if located near a waterway, beach etc; 

8   lack of proper maintenance, service or care of the gate and Unit; 

9   any unauthorised modification to the Unit; or 

10 damage caused by insects, pests or other after sale damage caused by events or accidents 

    outside Chamberlain’s reasonable control and not arising under normal and standard operating  

    conditions.

NB: A General Purpose Outlet (GPO) ie: power point must be supplied by the consumer as this 

electrical fitting does not form a part of the Unit (opener).

If this Chamberlain Limited Warranty does not apply, you may have rights available to you under the 

Australian and New Zealand consumer protection laws.

Liability – Australia only

 

Except as set out in the Australian Consumer Law (being Schedule 2 of the Competition and 

Consumer Act 2010) (as amended, consolidated or replaced): 

1 all other guarantees, warranties and representations in relation to the Unit or its supply are 

   excluded to the extent that Chamberlain can lawfully exclude them; and 

2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages 

   arising in connection with the use, or inability to use, the Unit, other than those which were 

reasonably foreseeable as liable to result from the failure.

Liability – New Zealand only

 

Except as set out in the Fair Trading Act 1986 and the Consumer Guarantees Act 1993 (as 

amended, consolidated or replaced): 

1  all  other  guarantees,  warranties  and  representations  in  relation  to  the  Unit  or  its  supply  are                                                   

   excluded to the extent that Chamberlain can lawfully exclude them; and 

2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages  

   arising in connection with the use, or inability to use, the Unit, other than those which were 

   reasonably foreseeable as liable to result from the failure.

Note

 

Chamberlain reserves the right to change the design and specifications of the Unit without prior 

notification. Some features or accessories of the Unit may not be available in certain markets or 

areas. Please check with your distributor.

Chamberlain service centre contact details

114A5435B

WARRANTY

Содержание MGLDK

Страница 1: ...Gate Opener MGLSK MGLDK MGLSK LV MGLDK LV Installation and Operating Instructions Owners Copy SAVE THESE INSTRUCTIONS for future reference gomerlin com au gomerlin co nz Visit the Swing L 300 landing...

Страница 2: ...ates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in minor or moderate i...

Страница 3: ...y respecting the given safety distances in accordance with the AS NZS 60335 1 in conjunction with AS NZS 60335 2 103 and or with safety devices e g safe edge Testing of the safety function of the driv...

Страница 4: ...Learning 20 Remote Control Behaviour 20 IR Behaviour 20 Input Command 21 Pedestrian Command 21 Delay Motor 2 in Open and Close Direction 21 22 Timer To Close TTC 22 Reversal Time 23 E Lock Ram Blow Mo...

Страница 5: ...g SPECIFICATIONS SWING L 300 MGLSK MGLDK MGLSK LV MGLDK LV 1 1 2 3 4 5 6 7 8 9 10 11 12 13 Manual 14 Quick Reference guide 15 SALES KIT INVENTORY MGLSK MAINS VOLTAGE 240V OR MGLSK LV LOW VOLTAGE 24V S...

Страница 6: ...Live Post Bracket 7 2 x Hairpin Clip 8 Clevis Pin 9 8 x M8x60 Masonry Anchors 10 2 x Gate Mounting Bracket 11 4 x M10x30 Bolts 12 2 x 13mm Bolt and Washer 13 2 x Four Button Remotes E970M 14 Quick Ref...

Страница 7: ...4V SWING GATE OPENER LINEAR ACTUATOR DUAL KIT OVERVIEW OF THE GATE OPENER 4 Gate Opener MGLX Remote Control Single Swing Gate Control Box MGEB or MGEB LV Control Box MGEB or MGEB LV Gate Opener MGLX R...

Страница 8: ...MGLDK LV low voltage 24V sales kit Transformer Box mounted near 240V power supply MGTR3 120VA NOTE Only required for MGLDK LV low voltage 24V sales kit Gate Opener MGLX Remote Control Single Swing Ga...

Страница 9: ...se to the opener by a licensed electrician 2 The 24V AC opener will require a low voltage power supply from the transformer box MGTR3 120VA to the gate opener 3 The recommended cable sizes for the con...

Страница 10: ...55mm Max 350mm w o hardstops Max 300mm with hardstops 95mm 137mm figure 1 figure 2 figure 3 DETERMINE THE POSITION OF THE POST BRACKET 7 1 Determine the A and B dimension in base on the opening angle...

Страница 11: ...osition the gate mounting bracket as shown figure 3 6 Temporarily secure the gate bracket to the gate with a clamp 7 Manually open and close the gate to the required positions Ensure the opener does n...

Страница 12: ...not supplied 4 Move the gate to the open position and secure the hardstop in the desired position using the Allen key Re engage the release mechanism 5 If the internal opener hardstops are not used i...

Страница 13: ...pping It is advised that you must have full view of the gates when programming the logic board Install the control box in an appropriate and accessible position The installation has to be done in acco...

Страница 14: ...otor1 Connection NOTE The opener wired to the MOTOR 1 terminal will always open first and close last 1 Feed the motor1 cable through the selected cable gland 2 Connect motor cables to the MOTOR1 termi...

Страница 15: ...5 5 9 10 12 10 0 0 0 0 4 3 2 1 1 2 3 3 1 2 1 2 12 13 14 4 11 10 9 8 7 6 5 1 3 2 3 4 2 1 3 2 1 2 1 3 2 1 3 2 1 2 1 1 2 1 2 2 1 2 1 1 2 1 2 5 4 3 2 1 6 7 8 9 10 2 1 1 1 1 2 1 1 1 1 IN1 IN1 IN2 IN2 IN3...

Страница 16: ...nsor can only be connected to the Edge inputs 1 Remove the 8 2k resistor from the Edge inputs 2 Connect the 8 2k compatible edge sensor to the Edge inputs EDGE SE SE IR SENSOR GND IR3 IR2 IR1 COMMAND...

Страница 17: ...change the value on display The programming of the boards is divided in two steps 1 Basic including Initial Setup 2 Advanced Password Protected Settings Initial Set up includes Selection of motor typ...

Страница 18: ...E Lock E Lock 30 Ram Blow Setup additional electronic lock E Lock or Mag Lock options 31 Flashing Light Setup flashing light accessory 32 Pre Flashing Adjust pre flashing of flashing light accessory 3...

Страница 19: ...splayed on the LCD 5 Press the P button to select The screen will change to show PRESS HOLD GATE OPENING YES P NO S 6 Press and hold The gate will start to move a If it moves in the OPEN direction pre...

Страница 20: ...tons to navigate through the options 3 You can select the following options OPEN CLOSE OPEN OPEN STOP CLOSE STOP OPEN STOP CLOSE OPEN OPEN ONLY 4 To confirm the setting press the P button to save and...

Страница 21: ...ing options No Second Delay Second Delay 3 Second Delay 4 Second Delay 4 To confirm the setting press the P button to save and return to the main menu screen S P MAIN MENU DELAY MOTOR 2 OPEN figure 1...

Страница 22: ...ELAY MOTOR 1 CLOSE figure 1 TIMER TO CLOSE TTC 29 Within the Basic Setting navigate through the menu screen until you find MAIN MENU TIMER TO CLOSE 1 Press the P button to enter this setting figure 1...

Страница 23: ...COND REVERSAL S P REVERSE TO LIMIT S P CLOSE REV TO OPEN LIMIT OPEN REV 2 SECONDS figure 1 figure 2 figure 3 figure 4 BASIC SETTINGS E LOCK 31 Within the Basic Setting navigate through the menu screen...

Страница 24: ...U FLASHING LIGHT 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Disabled Continuous Flashing 4 To con...

Страница 25: ...ind MAIN MENU SOFT HARD START SETTING 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Soft Hard Start...

Страница 26: ...WORD CHANGE PASSWORD S P ENTER OLD PW 0000 S P ENTER NEW PW 0000 figure 1 figure 2 figure 3 CHANGE PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD by pressing the and or buttons...

Страница 27: ...e force by 15 30 or 50 4 To confirm the setting press the P button to save and return to the main menu screen PASSWORD 38 ENTER PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD b...

Страница 28: ...you find MAIN MENU SPEED MOTOR 1 2 CLOSE PW 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can increase the speed by 10 20 30 or 50 In...

Страница 29: ...this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Execute Factory Reset Exit 4 To confirm the setting press the P button to save and...

Страница 30: ...NDBY screen NOTE The transmitter s supplied with your opener are preprogrammed by the factory If you purchase additional transmitters the gate opener must be programmed to accept the new transmitter c...

Страница 31: ...n gate opener is installed Purchase the gate myQ Connectivity Kit that includes 1 x myQ Gateway and 1 x 772ANZ Protector System Safety IR Beams Ensure the 772ANZ Protector System Safety IR Beams or GP...

Страница 32: ...the gate myQ Connectivity Kit or as an individual accessory NOTE The Protector System Safety IR Beams 772ANZ must be installed and operational for myQ to operate myQ Gateway Connect the myQ Gateway b...

Страница 33: ...BER from the bottom label of the myQ Gateway The serial number is a series of ten characters 0 9 or a f Be sure to use the correct characters e g a zero 0 instead of an O and keep the character spacin...

Страница 34: ...m Check for incorrect accessories wired into the IR terminals Check the Protector System for alignment or an obstruction Auto reset once obstruction is clear or Protector System is realigned may take...

Страница 35: ...te Auto reset once the issue has been resolved may take up to 16 seconds ERR MOTOR1 RPM ERR MOTOR2 RPM Motor is stalled or RPM is damaged Check if the motor is stalled or RPM is damaged Auto reset onc...

Страница 36: ...t shown 18 002A2331 6 Pin Wire Harness not shown 19 Model Vary Flashing Lamps not shown 20 Model Vary Sounders not shown 21 PU100 Emergency Stop Switch not shown 22 AT000 Timer 24h not shown WARNING T...

Страница 37: ...GGS1000 Articulated Arm Single Articulated Arm Dual Linear Arm Single Linear Arm Dual 2nd Direction Motor 1 Press Hold Gate Opening Yes P no S Change Direction P to Execute 3rd Direction Motor 2 Chang...

Страница 38: ...ontrol Behaviour Open Only Open Stop Close Stop Open Stop Close Open Open Close Open IR 1 2 3 Behaviour IR1 2 3 CLOSE DIR IR1 2 3 OPEN DIR IR1 2 3 OPEN CLOSE DIR IR1 2 3 CLOSE DIR IMMEDIATE CLOSE Inpu...

Страница 39: ...ing TTC 20 Seconds Setting TTC 30 Seconds Setting TTC 45 Seconds Setting TTC 1 Minute Setting TTC 2 Minutes Setting TTC 3 Minutes Setting TTC 5 Minutes Disable Ram Blow 1 Second Ram Blow 2 Seconds Rev...

Страница 40: ...30 Seconds 45 Seconds 60 Seconds 90 Seconds Soft Hard Start Setting 120 Seconds 180 Seconds 240 Seconds 300 Seconds Disabled 1 Second 2 Seconds 3 Seconds 4 Seconds 5 Seconds Soft Start Enabled Hard S...

Страница 41: ...Increase 30 Increase 50 Soft Stop Speed PW Factory Default Learned Speed Decrease 10 Decrease 20 Decrease 30 Decrease 50 Increase 10 Increase 20 Learned Speed Increase 10 Increase 20 Increase 30 Incre...

Страница 42: ...or gomerlin co nz warranty Get Connected with Visit www gomerlin com au or www gomerlin co nz for more details Additional purchase of the myQ Connectivity Kit is required to enable myQ functionality D...

Страница 43: ...43 NOTES...

Страница 44: ...period if you are concerned that the Unit may be defective call the Professional Dealer that sold installed the opener or our service centre on the toll free number below and a Chamberlain technician...

Отзывы: