background image

3

SAFETY INSTRUCTIONS

During operation, the gate should not under any circumstances obstruct public path ways and roads (public area). When using tools 

and small parts to install or carry out repair work on a gate, exercise caution and do not wear rings, watches or loose clothing.

To avoid serious personal injury due to entrapments, remove any locking device fitted to the gate in order to prevent damage to the 

gate.

Installation and wiring must be in compliance with your local building and electrical installation regulations. Power cables must only be 

connected to a properly earthed supply.

Disconnect electric power to the system before installation, maintenance, repairs or removing covers. A dual pole isolating switch 

must be provided to the mains power supply (permanently-wired installation) to guarantee all-pole disconnection (isolating switch or by 

a separate fuse). The repairs and electrical installations may be performed only by an authorized electrician. Emergency Stop Button 

must be installed for emergency case based on the risk assessment.

Any possible entrapment caused by the moving gate leaf(s) between gate & walls must be eliminated by respecting the given safety 

distances in accordance with the AS/NZS 60335.1 in conjunction with AS/NZS 60335.2.103 and/or with safety devices (e.g. safe 

edge). 

Testing of the safety function of the drive system is recommended to be carried out at least once a month. Refer also to 

manufacturers instruction of the gate system components.

After the installation a final test of the full function of the system and the safety devices must be made.

After installation and commissioning, all users must be instructed in the function and operation of the swing gate opener. 

It is important to make sure that the gate always runs smoothly. Gates which stick or jam must be repaired immediately. Employ a 

qualified technician to repair the gate, never attempt to repair it yourself. This device is not intended for use by persons (including 

children) with restricted physical, sensory or mental abilities or lack of experience or knowledge, unless they are supervised by a 

person responsible for their safety or have received instruction in how to use the device. If necessary, control equipment MUST be 

mounted within sight of the gate and out of reach of children. Children should be supervised to ensure that they do not play with the 

device. Do not allow children to operate push button(s) or remote(s). Misuse of the gate opener system can result in serious injury.

Содержание MGLDK

Страница 1: ...Gate Opener MGLSK MGLDK MGLSK LV MGLDK LV Installation and Operating Instructions Owners Copy SAVE THESE INSTRUCTIONS for future reference gomerlin com au gomerlin co nz Visit the Swing L 300 landing...

Страница 2: ...ates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in minor or moderate i...

Страница 3: ...y respecting the given safety distances in accordance with the AS NZS 60335 1 in conjunction with AS NZS 60335 2 103 and or with safety devices e g safe edge Testing of the safety function of the driv...

Страница 4: ...Learning 20 Remote Control Behaviour 20 IR Behaviour 20 Input Command 21 Pedestrian Command 21 Delay Motor 2 in Open and Close Direction 21 22 Timer To Close TTC 22 Reversal Time 23 E Lock Ram Blow Mo...

Страница 5: ...g SPECIFICATIONS SWING L 300 MGLSK MGLDK MGLSK LV MGLDK LV 1 1 2 3 4 5 6 7 8 9 10 11 12 13 Manual 14 Quick Reference guide 15 SALES KIT INVENTORY MGLSK MAINS VOLTAGE 240V OR MGLSK LV LOW VOLTAGE 24V S...

Страница 6: ...Live Post Bracket 7 2 x Hairpin Clip 8 Clevis Pin 9 8 x M8x60 Masonry Anchors 10 2 x Gate Mounting Bracket 11 4 x M10x30 Bolts 12 2 x 13mm Bolt and Washer 13 2 x Four Button Remotes E970M 14 Quick Ref...

Страница 7: ...4V SWING GATE OPENER LINEAR ACTUATOR DUAL KIT OVERVIEW OF THE GATE OPENER 4 Gate Opener MGLX Remote Control Single Swing Gate Control Box MGEB or MGEB LV Control Box MGEB or MGEB LV Gate Opener MGLX R...

Страница 8: ...MGLDK LV low voltage 24V sales kit Transformer Box mounted near 240V power supply MGTR3 120VA NOTE Only required for MGLDK LV low voltage 24V sales kit Gate Opener MGLX Remote Control Single Swing Ga...

Страница 9: ...se to the opener by a licensed electrician 2 The 24V AC opener will require a low voltage power supply from the transformer box MGTR3 120VA to the gate opener 3 The recommended cable sizes for the con...

Страница 10: ...55mm Max 350mm w o hardstops Max 300mm with hardstops 95mm 137mm figure 1 figure 2 figure 3 DETERMINE THE POSITION OF THE POST BRACKET 7 1 Determine the A and B dimension in base on the opening angle...

Страница 11: ...osition the gate mounting bracket as shown figure 3 6 Temporarily secure the gate bracket to the gate with a clamp 7 Manually open and close the gate to the required positions Ensure the opener does n...

Страница 12: ...not supplied 4 Move the gate to the open position and secure the hardstop in the desired position using the Allen key Re engage the release mechanism 5 If the internal opener hardstops are not used i...

Страница 13: ...pping It is advised that you must have full view of the gates when programming the logic board Install the control box in an appropriate and accessible position The installation has to be done in acco...

Страница 14: ...otor1 Connection NOTE The opener wired to the MOTOR 1 terminal will always open first and close last 1 Feed the motor1 cable through the selected cable gland 2 Connect motor cables to the MOTOR1 termi...

Страница 15: ...5 5 9 10 12 10 0 0 0 0 4 3 2 1 1 2 3 3 1 2 1 2 12 13 14 4 11 10 9 8 7 6 5 1 3 2 3 4 2 1 3 2 1 2 1 3 2 1 3 2 1 2 1 1 2 1 2 2 1 2 1 1 2 1 2 5 4 3 2 1 6 7 8 9 10 2 1 1 1 1 2 1 1 1 1 IN1 IN1 IN2 IN2 IN3...

Страница 16: ...nsor can only be connected to the Edge inputs 1 Remove the 8 2k resistor from the Edge inputs 2 Connect the 8 2k compatible edge sensor to the Edge inputs EDGE SE SE IR SENSOR GND IR3 IR2 IR1 COMMAND...

Страница 17: ...change the value on display The programming of the boards is divided in two steps 1 Basic including Initial Setup 2 Advanced Password Protected Settings Initial Set up includes Selection of motor typ...

Страница 18: ...E Lock E Lock 30 Ram Blow Setup additional electronic lock E Lock or Mag Lock options 31 Flashing Light Setup flashing light accessory 32 Pre Flashing Adjust pre flashing of flashing light accessory 3...

Страница 19: ...splayed on the LCD 5 Press the P button to select The screen will change to show PRESS HOLD GATE OPENING YES P NO S 6 Press and hold The gate will start to move a If it moves in the OPEN direction pre...

Страница 20: ...tons to navigate through the options 3 You can select the following options OPEN CLOSE OPEN OPEN STOP CLOSE STOP OPEN STOP CLOSE OPEN OPEN ONLY 4 To confirm the setting press the P button to save and...

Страница 21: ...ing options No Second Delay Second Delay 3 Second Delay 4 Second Delay 4 To confirm the setting press the P button to save and return to the main menu screen S P MAIN MENU DELAY MOTOR 2 OPEN figure 1...

Страница 22: ...ELAY MOTOR 1 CLOSE figure 1 TIMER TO CLOSE TTC 29 Within the Basic Setting navigate through the menu screen until you find MAIN MENU TIMER TO CLOSE 1 Press the P button to enter this setting figure 1...

Страница 23: ...COND REVERSAL S P REVERSE TO LIMIT S P CLOSE REV TO OPEN LIMIT OPEN REV 2 SECONDS figure 1 figure 2 figure 3 figure 4 BASIC SETTINGS E LOCK 31 Within the Basic Setting navigate through the menu screen...

Страница 24: ...U FLASHING LIGHT 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Disabled Continuous Flashing 4 To con...

Страница 25: ...ind MAIN MENU SOFT HARD START SETTING 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Soft Hard Start...

Страница 26: ...WORD CHANGE PASSWORD S P ENTER OLD PW 0000 S P ENTER NEW PW 0000 figure 1 figure 2 figure 3 CHANGE PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD by pressing the and or buttons...

Страница 27: ...e force by 15 30 or 50 4 To confirm the setting press the P button to save and return to the main menu screen PASSWORD 38 ENTER PASSWORD 1 Navigate the Menu screen till you get to MAIN MENU PASSWORD b...

Страница 28: ...you find MAIN MENU SPEED MOTOR 1 2 CLOSE PW 1 Press the P button to enter this setting figure 1 2 Press the or buttons to navigate through the options 3 You can increase the speed by 10 20 30 or 50 In...

Страница 29: ...this setting figure 1 2 Press the or buttons to navigate through the options 3 You can select the following options Execute Factory Reset Exit 4 To confirm the setting press the P button to save and...

Страница 30: ...NDBY screen NOTE The transmitter s supplied with your opener are preprogrammed by the factory If you purchase additional transmitters the gate opener must be programmed to accept the new transmitter c...

Страница 31: ...n gate opener is installed Purchase the gate myQ Connectivity Kit that includes 1 x myQ Gateway and 1 x 772ANZ Protector System Safety IR Beams Ensure the 772ANZ Protector System Safety IR Beams or GP...

Страница 32: ...the gate myQ Connectivity Kit or as an individual accessory NOTE The Protector System Safety IR Beams 772ANZ must be installed and operational for myQ to operate myQ Gateway Connect the myQ Gateway b...

Страница 33: ...BER from the bottom label of the myQ Gateway The serial number is a series of ten characters 0 9 or a f Be sure to use the correct characters e g a zero 0 instead of an O and keep the character spacin...

Страница 34: ...m Check for incorrect accessories wired into the IR terminals Check the Protector System for alignment or an obstruction Auto reset once obstruction is clear or Protector System is realigned may take...

Страница 35: ...te Auto reset once the issue has been resolved may take up to 16 seconds ERR MOTOR1 RPM ERR MOTOR2 RPM Motor is stalled or RPM is damaged Check if the motor is stalled or RPM is damaged Auto reset onc...

Страница 36: ...t shown 18 002A2331 6 Pin Wire Harness not shown 19 Model Vary Flashing Lamps not shown 20 Model Vary Sounders not shown 21 PU100 Emergency Stop Switch not shown 22 AT000 Timer 24h not shown WARNING T...

Страница 37: ...GGS1000 Articulated Arm Single Articulated Arm Dual Linear Arm Single Linear Arm Dual 2nd Direction Motor 1 Press Hold Gate Opening Yes P no S Change Direction P to Execute 3rd Direction Motor 2 Chang...

Страница 38: ...ontrol Behaviour Open Only Open Stop Close Stop Open Stop Close Open Open Close Open IR 1 2 3 Behaviour IR1 2 3 CLOSE DIR IR1 2 3 OPEN DIR IR1 2 3 OPEN CLOSE DIR IR1 2 3 CLOSE DIR IMMEDIATE CLOSE Inpu...

Страница 39: ...ing TTC 20 Seconds Setting TTC 30 Seconds Setting TTC 45 Seconds Setting TTC 1 Minute Setting TTC 2 Minutes Setting TTC 3 Minutes Setting TTC 5 Minutes Disable Ram Blow 1 Second Ram Blow 2 Seconds Rev...

Страница 40: ...30 Seconds 45 Seconds 60 Seconds 90 Seconds Soft Hard Start Setting 120 Seconds 180 Seconds 240 Seconds 300 Seconds Disabled 1 Second 2 Seconds 3 Seconds 4 Seconds 5 Seconds Soft Start Enabled Hard S...

Страница 41: ...Increase 30 Increase 50 Soft Stop Speed PW Factory Default Learned Speed Decrease 10 Decrease 20 Decrease 30 Decrease 50 Increase 10 Increase 20 Learned Speed Increase 10 Increase 20 Increase 30 Incre...

Страница 42: ...or gomerlin co nz warranty Get Connected with Visit www gomerlin com au or www gomerlin co nz for more details Additional purchase of the myQ Connectivity Kit is required to enable myQ functionality D...

Страница 43: ...43 NOTES...

Страница 44: ...period if you are concerned that the Unit may be defective call the Professional Dealer that sold installed the opener or our service centre on the toll free number below and a Chamberlain technician...

Отзывы: