Connect cable to the Opener:
Disconnect the mains Power from the Opener.
At the Powerhead Control Panel, pass both sets of cabling
through the top panel access hole.
Twist both WHITE wires together and both GREY wires together.
Connect the WHITES to the LEFT screw terminal of the 2-way
connector, and the GREYS to the RIGHT terminal (see fig 3)
Push the 2-way connector into the control panel quick release
terminals 2 & 3 (see fig 5).
Loop and secure the excess cabling above the opener assembly.
Test The Protector System
TM
operation:
Remove all obstacles from the path of the door. Connect the
mains Power to the opener.
1. Using a remote control, check the Opener operates in both
directions.
2. Obstruct the beams with the door fully OPEN, the door should
not move and the Courtesy light will Flash 10 times.
3. Obstruct the beams with the door travelling DOWN, the door
should STOP and return to the UP position. The Courtesy light
will Flash 10 times
4. Obstruct the beams with the door travelling UP, the door
should continue to the OPEN position.
Status indicators on the IR Beams:
Normal Operation --
Red leds “ON” constantly.
Low standby Mode --
Red leds “OFF”. (Leds
activate when door moves.)
IR Beams misaligned-
Red leds “FLASH”.
IR Beams obstructed--
Red leds “FLASH”.
For further diagnostics, refer to the TROUBLESHOOTING
section at the rear of the Opener Handbook.
Emergency Overide:
NOTE: The door canʼt be closed using the MyQ app if an
obstruction of Safety Beam failure has occurred.
However, if needed, the door can be closed by using the
programmed button of a Wireless Wall Button (E138M), a
Keyless Entry Keypad (E840M) or the GREEN button located on
the control panel.
Follow the process below:
With the door open Press the programmed button once and
release.
Press and “HOLD” the button again, and continue to HOLD untl the door has completely closed.
NOTE: If the button is released at any point during the downward movement, the door will stop and return to the OPEN
position. In this case repeat the previous process again. The “DOOR CLOSE” process will need to be performed each
time the door needs to be CLOSED, until the obstruction is removed or repairs are made to the Safety Beam System.
30 V DC
+
-
0
1
2
2
3
4
5
6
7
UP
DOWN
PROG
LEARN
(YELLOW)
INDICATOR
LED
Grey x
2
White x 2
3 x cable-tie mounts along
the rail
. In low ceiling
mount these ties mounts
to the side of the rail
2-WAY connector provided,
helps to connect the beams
to the Opener
Cable tie mount
Cable routing along the top of the rail to the opener.
White x2
Grey x2
14
3 x Cable Tie Mount
with cable tie
3 x Cable Tie Mount
with cable tie
3 x Cable Tie Mount
with cable tie
Beam 1
Beam 2
Opener
1 x 2-way connector
with leades and cable
colour mark
Cable End
solder termination
to 5 mm
fig. 3
fig. 4
fig. 5
INSTALL THE PROTECTOR SYSTEM
TM
(CONTINUED)