21
This is an adjustable, second stop position, that can be pre-set,
partially opened for ventilation, for pedestrian or pet access.
It is only operational with hand held remote controls, not
Wireless Wall Controls (E138M).
MyQ Activation:
It is not a normal feature of the MyQ phone
App, however, from the pre-set position, an open door can be
fully “CLOSED”ʻ but a closed door cannot be “OPENED” to the
pre-set position.
To Activate this feature:
1.Start with the door fully
CLOSED
(fig. 1). Drive the opener UP
(fig. 2) and stop at the position required for
PET
access.
2.Enter ventilation activation mode by pressing the
PROG
and
UP
buttons together for 3 seconds (fig. 3). Release when the
Courtesy light flashes once.
3.Press the Remote Control button that you have allocated for
this feature (fig. 4). Do not use the button already allocated
for normal operation. The Courtesy light will flash once when
the code is accepted.
TEST:
Press the Remote Control once, and door will close, press
again, and door will return to the preset position.
If the door is above the preset position, when the button
is pressed, it will fully close.
To Deactivate this feature:
1.Start with the door fully
CLOSED.
2.Enter PET deactivation mode by pressing the
PROG
and
UP
buttons together for 3 seconds (fig. 3). The Courtesy light will
flash twice, indicating the deactivation has occurred.
NOTE: Erasing all remote control codes, as in the Wireless
programming section, will also delete this feature.
VENTILATION MODE - PARTIAL OPENING FEATURE
Indicator L
ED
Indicator L
ED
Door Fully Closed
fig. 1
fig. 3
or
27
1
service
www
m
@
m
B
B
A
2
114A3361
For Service Call
Installation Date
3
132A2900
RI SK OF EN TR
APM EN T
Re pe a t Sa fe t y Re ve r se Te st m on t h ly. D oor
m u st r e ve r se on con t a ct w it h a 4 0 m m obst a cle
pla ce d on t h e floor . M a k e n e ce ssa r y a dj u st m e n t s.
AUTOM ATI C D RI V E:
Ke e p a w a y fr om t h e a r e a of t h e door sin ce it m a y
ope r a t e u n e x pe ct e dly.
EM ERGEN CY RELEASE:
To r e le a se , pu ll dow n fir m ly on t h e r e d h a n dle .
114A3361
For Service Call
Installation Date
l
l
26
INSTALL WARNING LABELS
Three warning labels are provided with this opener: attach as indicated in the fig 1 to a clean and suitable surface.
1. Risk of entrapment: (English version) - place close to a fixed Wall Control(1).
2. EMERGENCY Release/Service label: - place on the Manual Release cord (2).
3. WARNING Child Entrapment: (triangle label) - place on a low inside panel of the door (3).
fig. 4
fig. 1
Indicator L
ED
fig. 2