Merlin CK 1000L Скачать руководство пользователя страница 20

'· 

shunt trip-

u ndervoltage 
trip device 

[!] 

ensure that  b reaker  is 

discharged or trip it by  pushing the 
red trip button 

remove the  screws 

and  open 

front  cover 

shunt  trip  and  undervoltage 

tnp must  be  1nstalled in left  s1de 

ONLY 

I1J 

when the  breaker  is  operated 

by a  rotary  operating  handle,  the 

accessory  is  latched  by  another 
leaf  spring 

slide  the  upper  side  of the 

accessory  below  the  plastic hook 

1n  such a  position that you  have 

the  wire fixing  screws  facing you 

Push  down  the  lower  side  stra1ght 

down until it  is  latched by the  leaf 

spring 

electrical  data 
shunt trip 

catalog  voltage 

inrush 

number 

current 

36437 

60Hz  120V 

2.5A 

36446 

240V 

0.3A 

36446 

480V 

0.5A 

36447 

600V 

1A 

36434  DC 

12V 

3.8A 

36435 

24V 

11

36436 

48V 

S.SA 

36437 

125V 

2.5A 

------------- � .. 

undervoltage trip 

catalog  voltage 

sealed-in 

number 

current 

36418 

60Hz  120V 

OOSOA 

36419 

240V 

0.020A 

36420 

480V 

0.014A 

36421 

600V 

0.010A 

36410 

DC 

24V 

0  037A 

36411 

48V 

0.022A 

36412 

125V 

0.014A 

'\ 

�� 

www 

. ElectricalPartManuals 

. com 

Содержание CK 1000L

Страница 1: ...991 678a installation instructions molded case circuit breaker CK400 CK800 CK1200 CK1000L w E l e c t r i c a l P a r t M a n u a l s c o...

Страница 2: ...70 Ct 1 rl 4 l 85 I 17 f I 1 I I 9 44 I j 240 I I I I t t __ 2 95 I 1 1 75 27dia 07 19 _ 7 87 19 4 holes 5 200 5 drawout mounting to panel rear connection 8 26___ 210 on base plate 08 186 1 31dia I 7...

Страница 3: ...the breaker until tne disconnected position 1 is shown on the position indicator indexing lever caution push indexing lever down before operating racking handle to prevent mechanism damage I move slig...

Страница 4: ...sition and insert it into the mechanism II Caution push indexing lever down before operating the handle Position 2 is shown put the racking lever in the upright position II remove the breaker connecti...

Страница 5: ...3751b in 1200A or 2751b in SOOA Replace front terminal cover and tighten to 91b in bus bar connection OJ remove front short terminal cover 121 connect bars to terminals and trghten to 400ib in Replace...

Страница 6: ...er II remove rear terminal cover II remove pressure type terminal remove retaining clips and nuts I mount screws with retaining clips nuts and washers replace rear terminal cover and tighten the 4 scr...

Страница 7: ...al C1 undervolta terminaiD1 C2 _ location of electrical accessories on fixed mounting circuit breakers I 3 au 11 overcurrent trip switch terminal 81 84 ult indicators control power minal F11 F12 3 aux...

Страница 8: ...the cover Install the mounting screws add accessory identification and wiring label to left side of the circuit breaker 12 auxiliary switch a use a buzzer or light indicator attached to 11 and 14 ter...

Страница 9: ...m using resetting push button for remote resetting For other diagrams refer to technical manual m secure the motor operator using the fixing screw and replace black cover caution operate up and down t...

Страница 10: ...inal using a scewdriver and knock out one of the precut grooves m replace terminal Caution open circuit breaker and disconnect control power before removing the accessory cover by a screw on the break...

Страница 11: ...e sure to replace the trip unit transparent cover keeping an access to RESET push button Refer to main technical manual for characteristics and time current curves resetting caution in case of trippin...

Страница 12: ...L_j OJ open the circuit breaker and insert the adaptor into the slot motor operator I OJ open the front transparent cover and turn the breaker OFF 2 m extend the two parts making sure that the circuit...

Страница 13: ...t the circuit breaker from tripping under overcurrent conditions The handle will continue to indicate ON In the third position of padlocking the handle passes beyond the possible door cutout enabling...

Страница 14: ...the breaker see page 3 until the disconnected or withdrawn position m one padlock can be inserted on left and right side 7 i f3l note breaker can also be lOcked in such position by the mean of a KIRK...

Страница 15: ...991678a installation instructions molded case circuit breaker CK400 CK800 CK1200 CK 1000L w E l e c t r i c a l P a r t M a n u a l s c o...

Страница 16: ...f 1 w w w E l e c t r i c a l P a r t M a n u a l s c o m...

Страница 17: ...ling plan front connection drawout mounting 10 panel rear connection La 2a 1 I 210 on base plate 1 30 I 33 5 51 J 91 14o II 23 11 7 32 I 1a6 f i 8 11 206 optional cutout for secondary disconnecting bl...

Страница 18: ...w w w E l e c t r i c a l P a r t M a n u a l s c o m...

Страница 19: ...rmonal fault indicators T21 T21 control power c J termonal F11 F 12 exter nal neutral 1 3 auxiliary sensor 1 alarm switch term1nal T1 T2 cat no 36402 3 auxiliary switches I 11 12 14 1 i2 3 shunt trip...

Страница 20: ...hook 1n such a position that you have the wire fixing screws facing you Push down the lower side stra1ght down until it is latched by the leaf spring Ii I I electrical data shunt trip catalog voltage...

Страница 21: ...w w w E l e c t r i c a l P a r t M a n u a l s c o m...

Страница 22: ...nto the groove in such a position that you have the wire fixing screws facing you Push down the upper side straight down until it is latched by the leaf spring electrical data voltage V 2 auxiliary 1...

Страница 23: ...tall the mounting screws add accessory identification and wiring label to left side of the circuit breaker 12 auxiliary switch a use a buzzer or light indicator attached to 11 and 14 terminals and rep...

Страница 24: ...etting push button for remote resetting For other diagrams refer to technical manual m secure the motor operator using the fixing screw and replace black cover caution operate up and down the manual o...

Страница 25: ...ed by a screw on the breaker Each terminal may be connected by one stranded copper wire 1 8 to 14 AWG Cable strip length 3 8 approx In the factory these terminals are facing towards the top of circuit...

Страница 26: ...nit transparent cover keeping an access to RESET push button Refer to main technical manual for characteristics and time current curves resetting caution in case of tripping due to overcurrent or grou...

Страница 27: ...breaker from tripping under overcurrent conditions The handle will continue to indicate ON In the third position J of padlocking the handle passes beyond the possible door cutout enabling to padlock...

Страница 28: ...ker see page 3 until the disconnected or withdrawn position 5 16 dia max 08mm max one padlock can be inserted on left and right side 131 note breaker can also be locked in such position by the mean of...

Отзывы: