
COPYRIGHT © 2003 MERIT INDUSTRIES, INC.
PM0378-07 MEGATOUCH COMBO JUKEBOX™ OWNER’S MANUAL 37
DIP SWITCH SETTINGS IN FORCE GAMES
The following tables provide information on the functionality of the hard DIP switches in
FORCE games. Make sure to read the information in the “Notes” column to determine what
is affected when performing these functions. After performing any DIP switch function,
make sure to follow the instructions on the screen. In most cases, you will be instructed
to reset the DIP switch in order to reboot the game. If you fail to reset the DIP switch before
rebooting, it could result in corruption of the hard drive.
FORCE 2003/2004 & MAXX Ruby/Sapphire
Bank
Position
Function
Usage/Notes
DS 2
8
Motherboard
configuration &
checksum test
•
Configures the CMOS settings on the motherboard to
Merit specifications
Checks the files on the hard drive.
A checksum test should be performed when the game is
locking up or rebooting while being played or while in the
attract mode. If the test fails, the program should be
reloaded onto the hard drive. After reloading, perform
another checksum test. If it fails again, the hard drive
should be replaced.
DS 2
6
Hardware
configuration
•
Identifies system hardware and configures the
motherboard.
A hardware configuration occasionally needs to be
performed after a kit is installed and the touchscreen is not
responding to touch or the calibration is off.
DS 2
5 & 7
Memory clear for
TournaMAXX™
and
TouchTunes®
•
Clears the login name, password, access phone
number, and all call-in settings for TournaMAXX™
users.
•
Clears all the loaded albums for TouchTunes® users.
•
Clears current books, coin-in, high scores and resets the
software options.
A memory clear should be performed when a game is not
able to connect to TournaMAXX™ and there is some
question about the information in the Dial-Up Network
Screen being correct. After performing a memory clear,
TournaMAXX™ setup information must be re-entered, and
an “Update From Server” should be performed.
NOTE: TournaMAXX™ games must perform an “Update
From Server” BEFORE performing a memory clear.
DS 2
4 & 7
Complete
memory clear
•
Clears ALL memory on hard drive including the
TournaMAXX™ player database, TournaMAXX™
settings, advertising screens, bookkeeping, high scores,
coin-in, options, etc. It resets the game to the factory
defaults.
It also marks bad sectors on hard drive.
A complete memory clear should only be performed when
the game is locking up or resetting and it has passed the
checksum test. After performing a complete memory clear,
the player database should be reloaded, TournaMAXX
setup information must be re-entered, and an initial
connection and “Update From Server” should be performed.
NOTE: TournaMAXX™ games must perform an “Update
From Server” BEFORE performing a complete memory
clear.