22
LOCK
LIGHT
Slot
Figure 4
REMOVE COVER
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of the door at a
minimum height of 1.5 m where small children cannot
reach, and away from moving parts of the door and
door hardware. The installation surface must be
smooth and flat. If installing into drywall (Figure1), drill
4 mm holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be
mounted to a single gang box (Figure 2).
NOTE:
After installation, a green indicator light behind
the cover will indicate proper connection. If not lit, the
Lock and Light features will not function (reverse wires
to correct).
1. Strip 11 mm of insulation from one end of bell wire
and connect to the two screw terminals on back of
door control by color: white wire to 2 and white/red
wire to the 1 (Figure 3).
2. Remove white cover by gently prying at slot in top
of the cover with a small flat head screwdriver
(Figure 4). Fasten with 6ABx1-1/4"self-tapping
screws (drywall installation) or 6-32x1" machine
screws (into gang box) as follows:
• Drill and install bottom screw, allowing 3 mm to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic
housing.
Do not overtighten.
• Insert bottom tabs and snap on cover. (To remove
cover after mounting, gently pry at top with paper
clip or small flat head screwdriver.)
NOTE:
The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.
3.
(Standard installation only)
Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Strip 11 mm of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red
(Figure 5).
5. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
Bell Wire
Terminal
Screws
Bottom Mounting Hole
Top Mounting Hole
Drywall Anchors
Insulated
Staples
Screw 6ABx1-1/4"
(std installation)
Screw 6-32x1"
(pre-wired)
HARDWARE SHOWN ACTUAL SIZE
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED
INSTALLATION
LOCK
LIGHT
LOCK
LIGHT
To Replace
Insert Bottom Tabs First
Figure 1
STANDARD
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
Figure 3
DOOR CONTROL (BACK)
Figure 5
Red
Black
White
To release wire, push in
tab with screwdriver tip
Door Control
Connections
11 mm
7/16"
Strip wire 11 mm (7/16")
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 1.5 m, and
away from all moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
WARNING
CAUTION
WARNING
WARNING
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
WIRING INSTRUCTIONS FOR ACCESSORIES
The Protector System™: To opener terminals:
White to White and Black to Black.
Outside Keylock Accessory connections: To
opener terminals: Red/white to Red and White to
White.