Each radio remote control handset transmitter is
designed to operate with a unique radio ID code
and RF channel sequence. Each control panel
receiver is programmed to respond only to the
handset transmitter with the correct ID code/
RF channel sequence for which it is set. This
feature allows multiple systems to work in close
proximity to one another without interference.
If the handset goes out of range for more than
two seconds, all outputs except CONVEYOR
will turn off as a safety feature.
In the event that the handset becomes damaged
and a new one is needed, the control panel
receiver can be reprogrammed to respond to the
new control. Refer to Section 4.3.9 (Page 4-11)
All of the normal functions of the seed tender
can be controlled by the remote control handset.
29
5.4 WIRELESS REMOTE
TRANSMITTER
Each radio remote transmitter is designed to
operate with a unique radio ID code and RF
channel sequence. Each receiver is programmed
to respond only to the remote transmitter with the
correct ID code/RF channel sequence for which
it is set. This feature allows multiple systems to
work in close proximity to one another without
interference.
If the remote transmitter goes out of range for
more than two seconds, all outputs except
CONVEYOR will turn off as a safety feature.
In the event that a remote transmitter becomes
damaged and a new one is needed, the receiver
can be reprogrammed to respond to the new
remote transmitter. Refer to “10.1.3 Remote
Control Transmitter and Receiver Synchronization”
on page 50 of this manual.
All of the normal functions of the seed tender can
be controlled by the remote transmitter.
5.4.1 Functions of Keypad Buttons
Use the buttons on the keypad to operate the
desired functions of the seed tender.
1
2
3
5
4
6
7
8
9
10
POWER (1)
Press Power button (1) to turn remote transmitter
ON. Press and hold the button to turn it OFF.
To save battery life, the remote transmitter will
automatically turn off when it is idle (no functions
are used) for a period greater than the sleep time
(default is 15 minutes). Refer to “10.1.4 Changing
Sleep Time on the Transmitter” on page 51 to
change the sleep time on the transmitter.
NOTE:
The remote transmitter will NOT
automatically shut off as long as the receiver has
power applied to it.
ENG STOP (2)
Press Engine Stop button to turn OFF engine.
1
2
3
5
4
6
7
8
9
10
CONV (3)
The Conveyor button starts and stops the
conveyor belt. Press the INC button to start the
conveyor. Press STOP button to stop conveyor.
GATE 1 (4)
The Slide Gate 1 buttons open and close the slide
gate at the bottom of compartment 1. Press the
OPEN button to open the slide gate, and press
the CLOSE button to close the slide gate. The
opening can be varied to provide the desired flow
rate of seed onto the conveyor belt.
3.4 REMOTE CONTROL SYSTEM
3.4.1 Functions of Handset Buttons:
Use the buttons on the control to operate the
functions of the seed tender.
a. POWER:
Press Power button (a) to turn ON the
handset. Press and hold the button to turn
it OFF.
To save battery life, the handset will automatically
turn off when it is idle (no functions are used) for
a period greater than the sleep time (default is
15 minutes). Refer to Section 4.3.10 (Page 4-11)
to change the sleep time.
Note:
The remote control handset will NOT
automatically shut off as long as
the control panel receiver has
power applied to it.
b. ENG STOP:
Stop the engine with this button.
c. CONV - INC/STOP:
These Conveyor buttons start and stop the
conveyor belt.
The conveyor has 3 speeds. Press the INC
button once to start the conveyor at low
speed. Press the button again for medium
speed, and a third time for high speed. The
fourth time will return to low speed.
Note:
The conveyor will start at the last
speed used once stopped, always return
conveyor belt speed to low before stopping.
Fig 18 - Remote control handset transmitter
a
b
e
f
i
c
d
g
h
Содержание 405 SLD SEED EXPRESS
Страница 6: ...This page intentionally left blank...
Страница 20: ...2 10 Revised 08 2021 Operator s Manual 405 SLD Seed Express Bulk Seed Tender This page intentionally left blank...
Страница 68: ...5 2 Revised 08 2021 Operator s Manual 405 SLD Seed Express Bulk Seed Tender This page intentionally left blank...
Страница 72: ...6 4 Revised 08 2021 Operator s Manual 405 SLD Seed Express Bulk Seed Tender This page intentionally left blank...