SPECIFICATIONS AND MAINTENANCE
Page 76
90-864197020 MARCH 2002
0184
Boat Out Of The Water
AIR ACTUATED SINGLE POINT DRAIN SYSTEM
NOTE: This procedure is written for the air pump that is attached to the engine. However,
any air source can be used.
1. Remove the blue air pump from the engine.
2. Ensure that lever on top of pump is flush with the handle (horizontal).
3. Install air pump on the fitting in the air manifold.
77638
a
a -
Green Indicators
4. Pull lever on air pump up (vertical) to lock pump on the fitting.
5. Pump air into the system until both green indicators extend and water drains from both
sides of the engine. The port side will begin draining before the starboard side.
b
a
d
c
77955
77955
a
b
c
d
Closed Cooled Models
Seawater Cooled Models
a -
Blue Drain Plug Location
b -
Blue Air Pump
c -
Air Manifold
d -
Green Indicators
Содержание TowSport Inboards
Страница 1: ...2002 Mercury Marine Tow Sports Inboard MPI Models 90 864197020 302...
Страница 15: ...WARRANTY 90 864197020 MARCH 2002 Page 9 THIS PAGE IS INTENTIONALLY BLANK...
Страница 16: ...WARRANTY Page 10 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...
Страница 27: ...GETTING TO KNOW YOUR POWER PACKAGE 90 864197020 MARCH 2002 Page 21 THIS PAGE IS INTENTIONALLY BLANK...
Страница 28: ...GETTING TO KNOW YOUR POWER PACKAGE Page 22 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...
Страница 42: ...ON THE WATER Page 36 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...
Страница 92: ...SPECIFICATIONS AND MAINTENANCE Page 86 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...
Страница 98: ...TROUBLESHOOTING Page 92 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...
Страница 107: ...CUSTOMER ASSISTANCE INFORMATION 90 864197020 MARCH 2002 Page 101 THIS PAGE IS INTENTIONALLY BLANK...
Страница 108: ...CUSTOMER ASSISTANCE INFORMATION Page 102 90 864197020 MARCH 2002 THIS PAGE IS INTENTIONALLY BLANK...