SR-10K  Programming Guide

The 

COMMAND ENTRY MODE 

is selected by passing a valid 

MASTER

 card through the reader.

The intergral keypad allows direct data entry on the SR-10K.
The "*" key  is used to start a new command entry.  The '

#

' key terminates field entry.  For example,

selecting user slot 3 for the the 4-digit user slot entry in Command 20 can be entered as 4 digits:
'

0

','

0

','

0

','

3

', or it may be entered as '

3

', '

#

'.

single short beep

 indicates the acceptance of a digit, a 

double beep

 indicates the acceptance of

a field. 

 Three short beeps

 indicate that the command aborted due to an error.  One 

long beep

indicates succesful completion.

Command 12 - Delete a card, using the card

*

1 2

- select Command 12

user card

- read the card to be deleted from that slot

Command 13 - Delete a range of cards

* 1 3

- select Command 13

0-9

0-9

- select the first user number to delete: 00 to 99

0-9

0-9

- select the last user number to delete: 00 to 99

Command 11 - Delete a card, using the user slot

* 1 1

- select Command 11

0-9

0-9

- select the user number: 00 to 99

Command 10 - Add card(s)

* 1 0

- select Command 10

1-3

- select the user level: 1, 2, or 3

0-9

0-9

- select the user number: 00 to 99

user card

- read the card to be added in that slot

(

user card

- additional cards will be added into successive slots 

)

* 0-9

#

- any other action quits the "add loop"

RANDOM and Facility Code Database Mode Commands 

 (Commands 10 through 13)

Use these commands to manage the card holders if the RANDOM database mode was selected
Command 93 set to mode "0" - 

this mode is the facory default

.

Содержание SR-10K

Страница 1: ...Doc 10107 0007 Rev 1 04 Page 1 Mercury Security Corporation 2005 SR 10K SR 10K Mag Stripe Access System Users Guide...

Страница 2: ...ode 6 Two Door Access Control 14 Mode 7 Access Control with Door Bell Feature 15 Mode 8 Dual Output Toggle on Valid Access 15 Installation 16 Maintenance 17 Specifications 17 Dimensions and Typical Co...

Страница 3: ...p to 100 users factory default This mode allows the use of any magnetic stripe card with standard track 2 encod ing such as the MS SR10CC25 pre encoded packs of 25 cards or cards from many other acces...

Страница 4: ...isplay the status of an exter nal device connected to an input such as an alarm panel s armed disarmed indicator An Operating Mode is a collection of these functions intended for a specific applicatio...

Страница 5: ...etermines the installation wiring details and User Level assignment Lost Master Card Follow the steps outlined below to set a new Master Card in case the current Master Card is lost remove power from...

Страница 6: ...on Command 12 Delete a card using the card 1 2 select Command 12 user card read the card to be deleted from that slot Command 13 Delete a range of cards 1 3 select Command 13 0 9 0 9 select the first...

Страница 7: ...mmand 22 1 3 select the user level 1 3 0 1 0 9 0 9 0 9 enter the first user slot to activate 0000 through 1599 0 1 0 9 0 9 0 9 enter the last user slot to activate 0000 through 1599 Command 23 Delete...

Страница 8: ...s to indicate transfer in progress The transfer of the entire block mode card database 1 600 users may take up to 1 minute The completion of a succesful transfer is indicated with the long beep A tran...

Страница 9: ...with the Block Database Mode 4 The Block Number Command 94 must be set for Block Database Mode operation 5 In Facility Code Database Mode the digit count specifies the the number of card digits to rea...

Страница 10: ...rd read will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configuration Inputassignments Input I1 is connected to a...

Страница 11: ...the status of Input I2 User Level 2 and 3 A downward read will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configur...

Страница 12: ...rd pulses Output K2 allowing the momentary closure to simulate a key switch input to an alarm panel User Level Specifications User Level 1 Both downward and upward read will pulse Output K1 User Level...

Страница 13: ...etosimulate a key switch input to an alarm panel User Level Specifications UserLevel1 CardshavingthisUserLevelarerejectedifthecontactonInputI2isopen IfthecontactonInput I2 is closed Both downward and...

Страница 14: ...t to Output K2 and functions as the access control input User Level 1 users are valid only when a closed contact is presented to this input UpperLEDassignment The upper LED follows Input I2 displaying...

Страница 15: ...th Door Buzzer Control Description This mode is intended for applications where the outputs need to be toggled instead of the standard momentary pulse operation Both outputs are toggled Level 1 users...

Страница 16: ...l off moisture for outdoor mounting To avoid having ESD electrostatic discharge interfering with the operation of the reader the reader casing shall be grounded This can be accomplished be tying the m...

Страница 17: ...g nominal Interface Dimension 3 25 83mm W x 2 9 74mm L x 1 4 36mm H Weight 4 oz 120 g nominal Environmental Temperature 55 to 85 degrees C storage 40 to 75 degrees C operating Humidity Reader 100 RHN...

Страница 18: ...ss over cable Maximum distance between reader and interface is 500 feet using 22AWG wires 6 COND STRAIGHT Typical Wiring Configuration Communication Wiring Maximum total cable length 4 000 ft 1 200 m...

Страница 19: ...nap track The new module dimension is 4 25 x 2 75 inches Connection to the card reader is also changed from modular jack to a screw terminals for more convenient termination GND BLK BZR ORG LED BRN CL...

Отзывы: