DTS DUAL CONSOLE REMOTE CONTROL WITH CAN TRACKPAD
Page 10 / 17
90-889224 MAY 2006
DTS System Calibration - Non-Shadow Mode Applications
1. Connect the CDS tool to the junction box.
2. Ensure that the ignition key switch is in the "RUN" position, and that the CDS tool is
communicating with the command module.
NOTE: If the red Mercury SmartComm icon is flashing, the system cannot establish a
connection with the SmartComm interface box. If the yellow Mercury SmartComm icon
is flashing, the SmartComm interface box is detected, but communication with the
command module cannot be established. Check the connections, and ensure the ignition
key is turned on.
3. Click on the Engine Select button to enter engine information. To calibrate the
command module:
a.
Set the make to "GENERIC".
b.
Set the model to "DTS Command Module".
c.
Enter the number of engines.
d.
Enter the engine serial number and click the OK button.
4. If necessary, click on the Toolbox button. Click on the Calibration and System Info
button.
NOTE: A command module city ID will appear in the helm 1 starboard outside location.
This is the default factory setting for all command modules regardless of engine helm
configuration.
DTS VESSEL CONFIGURATION
IMPORTANT: The DTS vessel configuration sets the location of each command module
connected to the DTS system. A vessel configuration must be completed on any DTS
installation regardless of the number of engines.
1. Click on the "DTS Vessel Configuration" tab.
2. Select the number of engines and helms. Press the "Next" button.
3. Ensure the ignition key switch for all engines are in the "RUN" position and the control
handles are in the neutral position. Press the "Next" button.
4. If there are multiple helms, select the helm and lever location to be configured. Move
the selected control handle to the reverse wide open throttle (RWOT) position. Press
the "Next" button.
5. After all handles have been adapted press the "Finished" button.
6. Turn the ignition key switch to the "OFF" position for all engines and return all control
handles to the neutral position. Press the "Next" button.
7. DTS Vessel Configuration is now complete.
DTS HANDLE ADAPTATION
1. Click on the "DTS Handle Adaptation" tab.
2. Select the number of engines and helms. Press the "Next" button.
3. Ensure the ignition key switch for all engines are in the "RUN" position and the control
handles are in the neutral position. Press the "Next" button.
4. Select the ERC type. If a foot throttle is installed, click the "Foot Throttle Installed"
box.
NOTE: In a dual console application, the "Console, port handle" and "Console, starboard
handle" will need to be selected individually.
5. Select the shift polarity. Normal is standard right hand rotation (clockwise), reverse is
left hand rotation (counterclockwise).