TEMPERATURE (For 600.219 only)
RANGE Temperature Range RESOLUTION
ACCURACY
0ºC ~ 400ºC
1ºC
±(1.5% rdg+5ºC)
TEMP.
400ºC ~ 1000ºC
1ºC
±(1.5% rdg+15ºC)
Note: Use “K” type thermocouple probe while measuring
temperature.
DIODE AND AUDIBELE CONTINUITY TEST
Range
Description
Test Condition
The approx. forward
voltage of the diode
under test will be
displayed on the LCD.
The forward DC current
is approx. 1mA, the
reversed DC voltage is
approx. 2.8V.
If the resistance of the
circuit under test is less
than 30 Ω, the built-in
buzzer will sound.
Open circuit voltage
approx. 2.8V.
OPERATING INSTRUCTION
DC VOLTAGE MEASUREMENT
1)
Connect the red test lead to the "V/ Ω" jack and the black
test lead to the "COM" jack.
2)
Set the Function / Range switch to the desired “
” range
. If
the voltage to be measured is not known beforehand, set
the range switch to the highest range and then turn down
range by range until satisfacto ry resolution is obtained.
3)
Connect the test leads to the source or load to be
measured.
4)
Read the voltage value displayed on the LCD along with the
polarity of the red test lead.