background image

 

“MERCOR” SA 

– The company reserves the right to modify and change the document 

3/11 

 

NOTE 

All previous issues of this O&M Manual expire on the date of issue hereof. 

This Operating and Maintenance Manual does not apply to any fans manufactured prior to this 

Manual's date of issue. 

 

1. FOREWORD__________________________________________________ 

This Operating and Maintenance Manual is addressed to users/operators of type mcr Bora jet fans. This 
document is intended to provide guidelines on the application, design, commissioning and operation of 
the product.  

 

 

Read  this  manual  thoroughly  before  installing  this  equipment  at  its  operating  site 
and commissioning.  

 
 

 
If  the  equipment  is  found  malfunctioning  or  defective,  contact  the  manufacturer  or 
their authorised representative. 

 
 

 

Due  to  the  continuous  product  improvement  policy,  we  reserve  the  right  to  change 
the product design in order to improve its performance and safety.  

 
 

The  design  of  the  fans  complies  with  the  essential  requirements  of  PN-EN  12101-3:2004  for  smoke 
exhaust fans. The design also meets the state of the art in technology, while assuring health and safety 
protection. 

 

 

 

2. MANUFACTURER'S DISCLAIMER__________________________________  

  The manufacturer shall not be liable for any consequences of non-intended use or misuse of the 

equipment. 

  DO  NOT  install  any  components  that  are  not  included  in  the  equipment  composition  or 

accessories.  

  Unauthorised modifications or alteration of this equipment is strictly prohibited.  

  Protect the equipment enclosure (casing) from mechanical damage.  

  Before  attempting  to  install  this  equipment,  verify  the  load  bearing  capacity  of  the  structural 

members to which the equipment is to be fastened. Unreliable fastening may result in damage or 
failure of the equipment and/or be hazardous to all nearby personnel.  

  This fan is not intended for forcing air with viscous pollutants that may settle on the equipment, 

and especially on its rotor.  

  This  fan  is  not  intended  for  forcing  air  with  corrosive  pollutants  that  may  be  detrimental  to  the 

equipment.  

  The maximum actual rotor RPM must never exceed the nominal (rated) RPM speed in operation. 

  The  manufacturer  shall  not  be  liable  for  any  injuries,  trauma  or  other  bodily  harm  caused  by 

misuse of this equipment. 

 
 
 

Содержание mcr Bora BO

Страница 1: ...Ul Grzegorza z Sanoka 2 80 408 Gdańsk tel 0 58 341 42 45 tel fax 0 58 341 39 85 OPERATIONAL AND MAINTENANCE MANUAL Jet fan mcr Bora Revision 19 06 27 4 FIRE VENTILATION SYSTEMS ...

Страница 2: ...e 4 4 3 Versions 5 5 IDENTIFICATION MARKINGS 5 6 DESIGN AND OPERATING PRINCIPLE 5 6 1 Design 5 6 2 Function 5 6 3 Dimensions and technical features 5 7 INSTALLATION 7 7 1 Pre assembly inspection 7 7 2 Location and assembly 7 7 3 Electrical connections 7 7 4 Commissioning 8 8 TRANSPORT STORAGE CONDITIONS 8 9 SAFETY MANUAL 9 10 MAINTENANCE SERVICING 8 11 WARRANTY TERMS CONDITIONS 9 FAN MEASUREMENT R...

Страница 3: ...st fans The design also meets the state of the art in technology while assuring health and safety protection 2 MANUFACTURER S DISCLAIMER__________________________________ The manufacturer shall not be liable for any consequences of non intended use or misuse of the equipment DO NOT install any components that are not included in the equipment composition or accessories Unauthorised modifications o...

Страница 4: ...re occurance The available versions include single direction fans with dual speed motor reversible fans with dual speed motor The fans can be installed indoors on suitable consoles with the motor in the horizontal orientation The operating temperature range for fans in general purpose ventilation systems is 20 C to 40 C The fan may force dry air only with a maximum particulate content of 0 3 g m T...

Страница 5: ...ing assembly and silencers The motor is coupled directly to an aluminium rotor on bearings and on the rotor the profiled blades are installed The angle and number of blades depend on the required thrust and capacity of the fan The motor bearings are high temperature resistant and maintenance free On the inlet and outlet side the engine is connected to silencers The medium which is fire gases and a...

Страница 6: ...00 2410 482 495 657 400 750 720 167 26 12 mcr Bora 500 500 2650 3060 533 547 708 480 780 750 200 30 14 mcr Bora 560 560 2650 3060 608 622 798 650 950 920 255 30 14 7 INSTALLATION_____________________________________________ The mcr Bora smoke exhaust jet fan is intended for use in rooms designed for moving air and fire gases in the fire zone 7 1 Pre assembly inspection_____________________________...

Страница 7: ...g through the gland and into the terminal box on the fan casing then connect the wiring to the terminals in accordance with the diagram shown in the box The electrical wire with the proper fire resistance rating is installed in standard by the manufacturer between the fan motor and the terminal box Each fan motor must be connected to the electrical power system through an overcurrent switch The sa...

Страница 8: ...omponents of the fan and or its motor the maximum relative humidity is 80 at 20 C the ambient temperature is between 20ºC and 40ºC no vibrations are present 9 SAFETY MANUAL________________________________________________ Read and understand this Operating and Maintenance Manual before commissioning and servicing the product The smoke exhaust fan is not hazardous when firmly attached to a ventilati...

Страница 9: ... or sales contract subject to Item 10 5 MERCOR SA has the right to extend the time of repair if the defect removal is complicated or requires purchase of custom components or spare parts 6 The warranty liability only covers all defects arising from causes present in the equipment at the date of sale 7 Defects caused by improper operation or otherwise as listed in Item 10 herein the buyer warranty ...

Страница 10: ...this Operating and Maintenance Manual and or good construction practice The equipment and or parts thereof with removed or damaged nameplate rating plate and or warranty seals 11 The buyer warranty rights holder is required to operate the equipment properly and carry out technical inspection and maintenance in accordance with the section MAINTENANCE AND SERVICING in the following Operating and Mai...

Страница 11: ...ent draw in steady state operation of the equipment MEASUREMENT RESULTS A U1 V1 W1 U2 V2 W2 NOTES Full name of the measuring technician Date measured Signature Return this Report immediately after completion of measurements to MERCOR SA Fire Ventilation Systems ul Grzegorza z Sanoka 2 80 408 Gdańsk and not later than within 8 weeks from the date of equipment purchase equivalent to the date of the ...