![Merck EMD Millipore NovAseptic Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/merck/emd-millipore-novaseptic/emd-millipore-novaseptic_installation-and-user-manual_1772766010.webp)
Installation
Use the Installation Checklist and the
Installation Qualification Checklist (in this
manual) as guides for installing the mixer and
initiating use. Use the Maintenance Checklist
as a guide for follow up care of the mixer.
For welding of the Tank Plate use GMP ATEX
Welding Instructions.
Install the GMP ATEX Mixer components in the
following order:
4
xxxxxx
5
2
1
3
1. Tank plate
2. Male bearing
3. Mixing head
4. Drive unit
5. Revolution counter
Male Bearing Installation
See NovAseptic
®
Mixer Male Bearing
Installation Guide 00101868PU for additional
information.
•
The vessel must be clean and completely
dry inside.
•
Do not use grip tools on bearing surfaces.
•
Follow all local safety codes before entering
the vessel.
•
Handle the male bearing with care.
Mounting the Male Bearing
1. Ensure proper position of the O-ring on the
male bearing.
2. For minimal friction, lubricate the visible
part of the O-ring with a small amount of
purified water.
H
2
O
360°
3. Remove the protective cap. Ensure that the thread
connection in the tank plate and male bearing are
clean, dry, and free from foreign material.
1
2
4. Tighten the male bearing clockwise by hand
into the thread of the tank plate, making
sure that it is aligned with the center line of
the tank plate.
1
2
5. Position the male bearing in the appropriate
tightening tool or multi-tool with a torque
wrench. Ensure that the tool fits the nut.
Tighten the bearing to metal-to-metal
contact by applying recommended torque
according to table below.
Important: Ensure metal-to-metal contact
by applying recommended torque in table
below. If bearing is not installed properly it
may come off.