> After 10 minutes, the charging procedure is automatically reinitiated if the temperature inside the
housing has fallen to below 70° Celsius.
> The charging procedure is reinitiated immediately as soon as the temperature inside the housing falls
to below 60° Celsius.
If the error repeats or persists, the Wallbox must be cooled and/or shaded more effectively at the instal-
lation site. If the error repeats or persists, the Wallbox must be checked and replaced if required: Contact
your local smart technical support.
Display
Description
Error F11:
The contactor inside the Wallbox doesn't close.
The LED flashes red once, green once
and then yellow three times.
Solution:
The Wallbox automatically reinitiates the charging procedure every 60 seconds. If the error oc-
curs for a second time, the charging procedure is reinitiated after 10 minutes. If this error repeats or per-
sists further, an internal malfunction has occurred and the Wallbox must be replaced. Take the Wallbox
out of operation (see „Taking the product out of and back into operation.“ on page 23) and switch off the
upstream MCB. Contact your local smart technical support.
Display
Description
Error F15:
Current monitoring has detected that the preset ma-
ximum load imbalance has been exceeded and has reduced the
maximum charging current.
The LED pulsates green and flashes
blue once.
Solution:
Charging operations may continue, but the charging output will be reduced. If the error repeats,
it is possible that a fault has occurred in the charging system of the vehicle or that the maximum load
imbalance setting must be checked. Contact your local smart technical support if required. In addition,
always consider the notices provided in the operating manual of the vehicle.
Display
Description
Error F16:
Data transfer to the integrated electrical current mo-
nitor is disrupted. The maximum charging current is limited to
10 A while this error occurs.
The LED pulsates green and flashes
red once.
Solution:
Charging operations may continue, but the charging output will be reduced. If this error repeats
or persists, an internal malfunction has occurred and the Wallbox must be replaced. Take the Wallbox
out of operation (see „Taking the product out of and back into operation.“ on page 23) and switch off the
upstream MCB. Contact your local smart technical support.