Unloading
Put the “loading-unloading” selector on “unloading” position – the unloading cycle
will start.
Make sure that the rotating system is well engaged.
Push the “general start” button- the unloading belt will move, and a proofer will turn
while the rolls are discharged.
Note:
If you put the “loading-unloading” selector on position 0 during the unloading
cycle, the equipment will stop. To restart it, put the selector back in unloading
position.
An emergency stop during the loading cycle causes the re-initialization
of the expansion chamber.
Control proofer
During the start, after the initialization of the proofer, release the turning system, then
put the “control proofer loading-unloading” switch in loading position, then push the
“control proofer search” button. The control proofer will position itself under the V
divider, and a classic loading cycle will start.
Once the loading has been completed, put the “control proofer loading-unloading”
switch back in “0”.
For unloading, engage the turning system again, and put the “control proofer loading-
unloading” switch in unloading position; then push the “control proofer search”
button. The control proofer will position itself below the unloading belt, and a classic
loading cycle will start.
Once the loading has been completed, put the “control proofer loading-unloading”
switch back in “0”.
Cleaning
When the MECAFORM VE expansion chamber is correctly initialized, push the
“germicide” button to start a 1-hour UV lamp unloading cycle. To stop this cycle,
push the “germicide” button again.
The purpose of this function is to kill mould by means of UV light.