2006
OPERATING MODES
Restart after sector power cut or emergency stop
After restoring power, press the “general start” button so that the equipment performs
an initialization cycle. Once the initialization has been completed, the dough proofer
resumes the production mode selected before the stop.
Initialization cycle
The MECAFORM VE expansion chamber initialization cycle must be performed as
follows at each restart after a start or an emergency stop:
- Forward movement of the unloading belt up to the detection cell.
- Forward movement of the proofer support chain up to the proofer detection cell.
- Afterwards, the V divider and the Realignment V open, and the unloading belt
makes another forward movement up to the detection cell.
- Forward movement of the proofer support chain up to the proofer detection cell.
Once all these operations have been completed, the machine is in initial position and
waits for the launch of a new production cycle.
Loading
During the restart (after an emergency stop or a production start) push the “general
start” button.
Check that the weigher is well connected.
Put the “loading-unloading” selector on “loading” position – the cycle will start.
Note:
An emergency stop during the loading cycle causes the re-initialization of the
expansion chamber.