CONTENTS

Regulatory Requirements

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Application. . . . . . . . . . . . . . . . . . . . . . . . . . 3

Approval. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Connections. . . . . . . . . . . . . . . . . . . . . . . . . 3

Mounting The DC58M+ . . . . . . . . . . . . . . . . 3

Compatibility with PABXs. . . . . . . . . . . . . . . . 3

Connection To Telephone Network . . . . . . . 4

Overview

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Operating Modes. . . . . . . . . . . . . . . . . . . . . 4

NVM Programming. . . . . . . . . . . . . . . . . . . . 4

Technical Specifications. . . . . . . . . . . . . . . . 4

Operation

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Three-Way Calling . . . . . . . . . . . . . . . . . . . . 5

Line Fault Monitor . . . . . . . . . . . . . . . . . . . . . 5

Temporary Out of Service. . . . . . . . . . . . . . . 5

Point ID Extended Format . . . . . . . . . . . . . . . 6

Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Installation

Plug-on Installation . . . . . . . . . . . . . . . . . . . . 6

Telephone Line Connections . . . . . . . . . . . . 7

NETLCD/TS900 Keypad Connections . . . . . . 7

Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Programming

Programming Menu . . . . . . . . . . . . . . . . . . . 9

Telephone Numbers. . . . . . . . . . . . . . . . . . . 10

Account Numbers . . . . . . . . . . . . . . . . . . . . 10

Reporting Channels . . . . . . . . . . . . . . . . . . . 10

Set/Day Channels. . . . . . . . . . . . . . . . . . . . . 10

Restore Channels . . . . . . . . . . . . . . . . . . . . . 10

Dialling Modes . . . . . . . . . . . . . . . . . . . . . . . 11

Test Call Period . . . . . . . . . . . . . . . . . . . . . . . 11

Point ID Extended Format . . . . . . . . . . . . . . . 11

Temporary Out of Service . . . . . . . . . . . . . . 11

Monitor Mode

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 12

Transmitted Data Specification . . . . . . . . . . 12

Typical Test Call . . . . . . . . . . . . . . . . . . . . . . 12

Other Monitor Messages. . . . . . . . . . . . . . . . 12

NVM Programming Form . . . . . . . . . . . . . . . 13

2

DC58M+ Installation Instructions

Содержание DC58M+

Страница 1: ...DC58M 8 Channel Digital Communicator Digi Modem Installation Programming Instructions...

Страница 2: ...int ID Extended Format 6 Modem 6 Installation Plug on Installation 6 Telephone Line Connections 7 NETLCD TS900 Keypad Connections 7 Testing 8 Programming Programming Menu 9 Telephone Numbers 10 Accoun...

Страница 3: ...l for the DC58M This product is manufactured to meet all European Economic Area Telecommunication networks requirements Connections Connection terminals on the DC58M are described as either Safety Ext...

Страница 4: ...present The NVM can be programmed by using a Menvier LCD Remote Keypad P No NETLCD TS900 REM and an engineer s interface lead P No NETEKI which will plug directly on to the DC58M Alternatively the NV...

Страница 5: ...call The unit then sends a Recall signal which is detected by the exchange as a request for a new line With a new line available the DC58M then attempts to connect with the ARC If the DC58M is connec...

Страница 6: ...ation A LED 1 Activity LED On whilst communicator is active Flashes on and off 4 times when successfully communicated with the ARC Flashes continuously when modem is in operation B Test Call Short the...

Страница 7: ...t and remove the bottom section from the master jack 6 Connect the cable from A and B terminals on the DC58M to the BT master jack terminals see Figure 4 7 A special insertion tool will be required to...

Страница 8: ...rily shorting the TEST CALL pins together see Figures 3 This will initiate a test transmission to the ARC The DC58M will not send a test call if there is a parallel hand set off hook 4 Trigger all the...

Страница 9: ...TO NO 2 2 3 4 8 REPORTS TO NO 3 2 3 4 8 Select channels that report to tel No 2 by pressing 1 8 Select channels that report to tel No 3 by pressing 1 8 SET DAY CHANNELS 4 Select Set Day Open Close ch...

Страница 10: ...ently Account Numbers This is a 4 digit number that the alarm receiving centre uses to identify the alarm site Up to three account numbers can be programmed Account numbers can only be programmed if t...

Страница 11: ...l details on the extended information refer to the relevant control panel Installation Manual This feature is only supported by relevant Menvier control panels for details on which control panels supp...

Страница 12: ...ld show Other Monitor Messages The following monitor messages may also be displayed 12 Monitor Mode DC58M Installation Instructions DC58M MONITOR Waiting for I D DC58M MONITOR Sending Data Dialling th...

Страница 13: ...Reports to No 1 Reports to No 2 Report to No 3 Set Day Channels Restore Channels Three way Calling Disabled o Enabled o Dialling Mode Consecutive o Alternative o All o Test Call Period Disabled o Dail...

Страница 14: ...14 Monitor Mode DC58 58M Installation Instructions This page is intentionally blank...

Страница 15: ...15 DC58 58M Installation Instructions Monitor Mode This page is intentionally blank...

Страница 16: ...per Security Ltd Security House Xerox Business Park Mitcheldean Gloucestershire GL17 0SZ England Product Support Tel 01594 545556 Between 09 00 and 17 00 Monday to Friday Product Support Fax 01594 545...

Отзывы: