background image

0

10

20

30

40

50

60

70

80

90

100

PSI

Clean, dry 

pressure supply

Device Under Test

0

50

100

150

200

250

300

350

400

450

500

PSI

Range : 0 ... 500 psig S/N: 811000

Application — Typical Setup

Page 6 of 8

Data Sheet CPC3000

Application — Setpoint entry options and function

0

1

2

3

4

5

0

20

40

60

80

100

Per

cen

t of S

etp

oin

t

Time (s)

Direct entry of setpoint using the numeric 

keypad: enter the setpoint value and press 

. The controller will then ramp up the 

   setpoint.

0

20

40

60

80

100

Per

cen

t of S

etp

oin

t

Steps changed at operator discretion 

Setpoint entry using the step keypad:step 

changes, automatically calculated as a 

percent of the user defined full scale limit, 

and indicated in percent FS or pressure 

units can be entered by pressing step keys 

 ) in any sequence.

Setpoint entry using jog keypads: 

setpoint can be increased or decreased 

in small or large steps using the jog 

keys 

 to reach a cardinal point on 

a dial gauge or step through a calibra-

tion sequence. 

Содержание CPC3000

Страница 1: ...tion facility all screens can be viewed in several different languages To enter the pressure setpoint the operator can choose between four input modes which can be selected using the corresponding tab The input modes are 1 The numeric key menu provides a way to enter a specific pressure set point value to be controlled 2 The step keypad menu provides defined steps programmed in pressure increments...

Страница 2: ...Barometer Port Exhaust Relief Port 12 3125 Page 2 of 8 Data Sheet CPC3000 Dimensions in inches Rear view Front view Side view Fan On Off switch Fuse Power supply Electrical connections and pressure ports rear view 10 1875 8 6875 5 5 7 375 Ethernet IEEE 488 USB ...

Страница 3: ...mH2O 4C mmH2O 20C cmH2O 20C mH2O 20C Pressure units user defined 2 multiplier from psi or Pascal Slew rate 3 seconds to stable flag 0 025 full scale pressure for a 10 pressure change typical into 150cc volume at pressures greater than 5 PSI Larger volumes can lengthen this time Controlling to pressures less than atmosphere can lengthen this time Overshoot 1 FS in high speed mode Control stability ...

Страница 4: ...ding a precise pressure at the test port VENT Vent mode vents the system and the device under test to atmospheric pressure Optional information can be displayed in the main menu by selecting the option in the setup menu User defined DUT control range limits configurable via SETUP optional display element Numeric keypad Delete selected set point Delete last entered digit Accept selected set point S...

Страница 5: ...ypad have values which correspond to the 3 last digits of the pressure reading and are used to incre ment the set point Triangles pointing up will increase the value and those pointing down will decrease it The smallest triangle increments the least significant digit by one the medium size triangle increments the least significant digit by ten andThe large triangle increments the least significant...

Страница 6: ...ter the setpoint value and press The controller will then ramp up the setpoint 0 20 40 60 80 100 Percent of Setpoint Steps changed at operator discretion Setpoint entry using the step keypad step changes automatically calculated as a percent of the user defined full scale limit and indicated in percent FS or pressure units can be entered by pressing step keys in any sequence Setpoint entry using j...

Страница 7: ...mand structures In addition to IEEE 488 the CPC3000 has Ethernet and USB communications making it remotely accessible to today s modern automation systems Trouble shooting the initial remote setup is made easy by viewing the remote monitor which displays the most recent commands sent and responses from the CPC3000 plus any error messages Options and accessories Barometric reference An optional bar...

Страница 8: ...y CPC3000 High Speed Pressure Controller Desk top version with bezel and handle Power cable 6 ft with plug Operating instructions NIST traceable calibration certificate Pressure adaptor fittings A2LA certificate Options Barometric reference 19 rack mounting kit Customized calibration system Accessories Additional pressure adaptor fittings All standard Mensor products are provided with a calibratio...

Отзывы: